Abstract

fetched live from OpenAlex

The proper reduction of noise inside CTscan Images remains crucial to achieve both better diagnosis results and clinical choices. This research analyzes through quantitative metrics the effectiveness of four popular noise reduction methods which include Fourier-based denoising and Wiener filtering as well as bilateral filtering and Contrast Limited Adaptive Histogram Equalization (CLAHE) applied to more than 500 CTscan Images. The investigated methods were assessed quantitatively through Peak Signal-to-Noise Ratio (PSNR) and Structural Similarity Index (SSIM) while Mean Squared Error (MSE) served as the additional metric for evaluation. The evaluated denoising methods revealed bilateral filtering as the best technique based on its 50.37 dB PSNR and 0.9940 SSIM together with its 0.5967 MSE. Denoising with Fourier-based methods succeeded in removing high-frequency noise however it produced PSNR of 25.89 dB along with SSIM of 0.8138 while maintaining MSE at 167.4976 indicating lost crucial Image information. The performance balance of Wiener filtering resulted in 40.87 dB PSNR and 0.9809 SSIM and 5.3270 MSE that outperformed Fourier denoising in SSIM yet demonstrated higher MSE. CLAHE produces poor denoising outcomes because it achieves the lowest PSNR of 21.51 dB together with SSIM of 0.5707, and the maximum MSE of 459.1894 while creating undesirable artifacts. This research stands out through a full evaluation of four denoising techniques on a big dataset to create more precise analysis than prior research. The research results show bilateral filtering to be the most reliable technique for CTscan Image noise reduction when maintaining picture quality and thus represents a suitable choice for clinical use. This research adds new information to medical imaging research about quality enhancement which directly benefits clinical diagnostics and therapeutic planning.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.007
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.362
Threshold uncertainty score0.488

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0070.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.023
GPT teacher head0.397
Teacher spread0.374 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueScientific Journal of Engineering ResearchSame topicAdvanced X-ray and CT ImagingFrench-language works237,207