MétaCan
Menu
Back to cohort
Record W4413107282 · doi:10.1007/s10334-025-01284-w

Polar Fourier transform in practice: its efficiency and characteristics in reconstructing radially acquired MRI images

2025· article· en· W4413107282 on OpenAlexaff
Fatemeh Rastegar Jooybari, Ali Aghaeifar, Elham Mohammadi, Klaus Scheffler, Abbas Nasiraei‐Moghaddam

Bibliographic record

VenueMagnetic Resonance Materials in Physics Biology and Medicine · 2025
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsUniversity of Toronto
FundersH2020 European Research CouncilUniversity of Southern California
KeywordsFourier transformPolarNuclear magnetic resonanceComputer scienceArtificial intelligencePhysicsComputer visionAstronomy

Abstract

fetched live from OpenAlex

OBJECTIVE: The Polar Fourier Transform (PFT) has been proposed as a direct alternative to gridding for reconstructing radially acquired MRI data. This study evaluates the feasibility of inline PFT implementation on a clinical MRI scanner and assesses its computational performance and image quality under acceleration. MATERIALS AND METHODS: PFT was implemented as modular components within the Siemens Image Calculation Environment, using a recursive numerical Hankel transform. Phantom and in vivo brain datasets acquired with 2D radial trajectories were reconstructed using both PFT and vendor-supplied gridding. Reconstruction time, SNR, artifact behavior, and spatial resolution were assessed across multiple undersampling levels (up to 8 ×), using simulations and repeated scans. RESULTS: PFT was successfully integrated with a runtime of ~ 6-9 × acquisition time. It exhibited spatially variant behavior, concentrating resolution in central region while shifting undersampling-induced blurring outward. Compared to gridding, PFT reduced structured streaks and better preserved image quality under acceleration. Gradient delay artifacts were reduced by alternating spoke polarity. Notably, the pituitary gland and basilar artery remained visible at high acceleration, highlighting preserved central fidelity. DISCUSSION: PFT enables effective inline reconstruction for radial MRI and preserves image quality in small central regions of interest under aggressive undersampling-supporting dynamic and ROI-focused applications.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.654
Threshold uncertainty score0.550

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.326
Teacher spread0.316 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueMagnetic Resonance Materials in Physics Biology and MedicineSame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207