MétaCan
Menu
Back to cohort
Record W4413117971 · doi:10.1186/s12891-025-08980-7

Evaluating the clinical outcomes of computer-assisted surgery and patient-specific instrumentation compared to conventional instrumentation in total knee arthroplasty, a randomised controlled trial

2025· article· en· W4413117971 on OpenAlexaboutno aff
Ziyang Dong, Yang Li, Yipu Zhang, Xiao Geng, Xinguang Wang, Yuhang Zheng, Junhao Feng, Zhencan Han, Hua Tian

Bibliographic record

VenueBMC Musculoskeletal Disorders · 2025
Typearticle
Languageen
FieldMedicine
TopicTotal Knee Arthroplasty Outcomes
Canadian institutionsnot available
FundersPeking University Third HospitalPeking University
KeywordsMedicineInstrumentation (computer programming)Sports medicineOrthopedic surgeryPhysical therapyTotal knee arthroplastyArthroplastyRehabilitationRandomized controlled trialClinical trialKnee surgerySurgeryMedical physicsOsteoarthritisInternal medicineAlternative medicinePathology

Abstract

fetched live from OpenAlex

OBJECTIVE: Computer-assisted surgery (CAS) and patient-specific instrumentation (PSI) are digital techniques to improve the accuracy of implant positioning in total knee arthroplasty (TKA), but their effects on clinical outcomes are still in dispute. The objective of this trial is to evaluate the efficacy and safety of CAS and PSI compared to conventional instrumentation (CI) in TKA. METHODS: A prospective randomized controlled trial was conducted. A total of 135 patients undergoing TKA were randomized into CAS group, PSI group and CI group with 45 patients in each group. Primary outcome is the coronal mechanical axis of lower extremity. Secondary outcomes include Femoral Rotation Angle (FRA) of the femoral prosthesis, operation time, perioperative blood loss, Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Forgotten Joint Score (FJS) and complications. RESULTS: Outliers of Hip-Knee-Ankle angle (HKA) were 24.4% in CI group, 17.8% in CAS group and 31.1% in PSI group respectively, and there was no significant difference among these 3 groups (P > 0.05). Outliers of FRA were 13.3% in CI group, 26.7% in CAS group and 11.1% in PSI group respectively with no significant difference (P > 0.05). Operation time was (66.67 ± 12.85)min, (81.67 ± 12.31)min and (52.78 ± 8.62)min in CI, CAS and PSI group. Operation time in CI was longer than PSI and shorter than CAS with significant difference (P < 0.01). There was no significant difference in comparison of blood loss, transfusion rate, postoperative WOMAC and FJS (P > 0.05). CONCLUSION: CAS and PSI, compared with CI, did not significantly improve clinical outcomes including lower limb alignment, rotation of femoral prosthesis, blood loss, transfusion rate, and function scores. However, CAS was associated with prolonged operation time, whereas PSI resulted in a reduced operation time. LEVEL OF EVIDENCE: Level II. TRIAL REGISTRATION: ChiCTR-INR-17,012,881 (registration date: 03/10/2017).

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.006
metaresearch head score (Gemma)0.010
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Randomized trial · Consensus signal: Randomized trial
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.007
Threshold uncertainty score0.031

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0060.010
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0060.004
Bibliometrics0.0010.001
Science and technology studies0.0010.002
Scholarly communication0.0020.001
Open science0.0010.001
Research integrity0.0030.003
Insufficient payload (model declined to judge)0.0070.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.040
GPT teacher head0.356
Teacher spread0.316 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designRandomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueBMC Musculoskeletal DisordersSame topicTotal Knee Arthroplasty OutcomesFrench-language works237,207