MétaCan
Menu
Back to cohort
Record W4413301273 · doi:10.3390/cancers17162676

Clinical Integration of NIR-II Fluorescence Imaging for Cancer Surgery: A Translational Evaluation of Preclinical and Intraoperative Systems

2025· article· en· W4413301273 on OpenAlexaff
Ritesh K. Isuri, Justin Williams, David Rioux, Paul Dorval, Wendy K. Chung, Pierre-Alix Dancer, Edward J. Delikatny

Bibliographic record

VenueCancers · 2025
Typearticle
Languageen
FieldEngineering
TopicNanoplatforms for cancer theranostics
Canadian institutionsPhoton Etc (Canada)
FundersNational Cancer InstituteNational Institutes of Health
KeywordsImaging phantomIndocyanine greenBiomedical engineeringFluorescence-lifetime imaging microscopyPreclinical imagingMaterials scienceIn vivoImage resolutionFluorescenceNuclear medicineMedicineOpticsPathology

Abstract

fetched live from OpenAlex

Background/Objectives: Back table fluorescence imaging performed on freshly excised tissue specimens represents a critical step in fluorescence-guided surgery, enabling rapid assessment of tumor margins before final pathology. While most preclinical NIR-II imaging platforms, such as the IR VIVO (Photon, etc.), offer high-resolution and depth-sensitive imaging under controlled, enclosed conditions, they are not designed for intraoperative or point-of-care use. This study compares the IR VIVO with the LightIR system, a more compact and clinically adaptable imaging platform using the same Alizé 1.7 InGaAs detector, to evaluate whether the LightIR can offer comparable performance for back table NIR-II imaging under ambient light. Methods: Standardized QUEL phantoms containing indocyanine green (ICG) and custom agar-based tissue-mimicking phantoms loaded with IR-1048 were imaged on both systems. Imaging sensitivity, spatial resolution, and depth penetration were quantitatively assessed. LightIR was operated in pulse-mode under ambient lighting, mimicking back table or intraoperative use, while IR VIVO was operated in a fully enclosed configuration. Results: The IR VIVO system achieved high spatial resolution (~125 µm) and detected ICG concentrations as low as 30 nM in NIR-I and 300 nM in NIR-II. The LightIR system, though requiring longer exposure times, successfully resolved features down to ~250 µm and detected ICG to depths ≥4 mm. Importantly, the LightIR maintained robust NIR-II contrast under ambient lighting, aided by real-time background subtraction, and enabled clear visualization of subsurface IR-1048 targets in unshielded phantom setups, conditions relevant to back table workflows. Conclusions: LightIR offers performance comparable to the IR VIVO in terms of depth penetration and spatial resolution, while also enabling open-field NIR-II imaging without the need for a blackout enclosure. These features position the LightIR as a practical alternative for rapid, high-contrast fluorescence assessment during back table imaging. The availability of such clinical-grade systems may catalyze the development of new NIR-II fluorophores tailored for real-time surgical applications.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.018

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.002
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.060
GPT teacher head0.371
Teacher spread0.311 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueCancersSame topicNanoplatforms for cancer theranosticsFrench-language works237,207