MétaCan
Menu
Back to cohort
Record W4413436315 · doi:10.1016/j.jtemb.2025.127729

Portable X-ray fluorescence of zinc and selenium with nail clippings – visit 3 of the Mother and Infant Nutrition Investigation (MINI)

2025· article· en· W4413436315 on OpenAlexafffund
David Fleming, Andrianna R. Scott, Jasmine A Ouellette, Jong Sung Kim, Abir Lefsay, Ying Jin, Jane Coad, Louise Brough

Bibliographic record

VenueJournal of Trace Elements in Medicine and Biology · 2025
Typearticle
Languageen
FieldPhysics and Astronomy
TopicX-ray Spectroscopy and Fluorescence Analysis
Canadian institutionsNova Scotia Health AuthorityDalhousie UniversityMount Allison University
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsSeleniumZincFluorescenceNail (fastener)ChemistryEnvironmental chemistryMedicineMaterials scienceMetallurgyPhysicsOpticsOrganic chemistry

Abstract

fetched live from OpenAlex

INTRODUCTION: Recent advances in portable X-ray fluorescence (XRF) have opened up the possibility of a rapid and cost-effective method for measuring elemental content in nail clippings. Two elements of particular interest for intake assessment through nail clipping measurement are zinc and selenium. The New Zealand-based Mother and Infant Nutrition Investigation (MINI) provides an ideal testing ground for the application of portable XRF in the measurement of zinc and selenium. Two aspects requiring further study with portable XRF are the optimal time of measurement and the optimal approach to energy spectrum analysis. METHODS: A subset of nail clippings from 20 mother-infant pairings were initially selected for analysis over three separate MINI study visits. This paper considers measurements from visit 3 (12 months postpartum). For portable XRF, a mono-energetic X-ray beam was used to excite characteristic X-rays from zinc and selenium. Individual XRF measurements were made for 60 s (real time). In each case, analysis of the elemental signal was performed in four different ways: (1) automated system output concentration; (2) element signal to total signal ratio; (3) element signal to Compton scatter signal; (4) element signal to coherent scatter signal. XRF results were compared against zinc and selenium concentrations obtained from a "gold standard" method of inductively coupled plasma mass spectrometry (ICP-MS). RESULTS: ICP-MS results from the visit 3 nail clippings determined a mean zinc concentration of 104 µg/g and a mean selenium concentration of 0.606 µg/g. Analysis of XRF energy spectra from 60 s measurements showed that zinc was clearly detected in all cases. The selenium signal was more challenging, but was also detected from all spectra. For both zinc and selenium, correlations between XRF results and ICP-MS concentrations were highly significant (p < 0.01) in all cases, with the zinc results more strongly correlated than selenium. Of the four approaches to XRF signal analysis, the three approaches involving an external software package provided superior results relative to the automated system output. Correlations of XRF results with ICP-MS concentrations were similar between these three approaches. CONCLUSION: ICP-MS concentrations for both zinc and selenium were found to be lower from visit 3 relative to results from visit 1 and visit 2. This may indicate overall dietary changes postpartum. Correlations of XRF results with ICP-MS concentrations suggest that a relatively short 60 s measurement time is adequate for a reliable zinc assessment, but not for selenium. Although correlations of XRF results with ICP-MS concentrations were similar between three different methods of spectra analysis, practical considerations may favor use of the element signal to total signal approach.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.012
Threshold uncertainty score0.034

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0010.000
Science and technology studies0.0010.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0100.002

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.282
Teacher spread0.272 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2025
Admission routes2
Has abstractno

Explore more

Same venueJournal of Trace Elements in Medicine and BiologySame topicX-ray Spectroscopy and Fluorescence AnalysisFrench-language works237,207