MétaCan
Menu
Back to cohort
Record W4414142842 · doi:10.3390/mining5030055

Numerical Investigation of Ultra-Long Gravity Heat Pipe Systems for Geothermal Power Generation at Mount Meager

2025· article· en· W4414142842 on OpenAlexaffabout
Yutong Chai, Wenwen Cui, Ao Ren, Soheil Asgarpour, Shunde Yin

Bibliographic record

VenueMining · 2025
Typearticle
Languageen
FieldEngineering
TopicThermodynamic and Exergetic Analyses of Power and Cooling Systems
Canadian institutionsCouncil of Canadian AcademiesUniversity of Waterloo
Fundersnot available
KeywordsCondenser (optics)Heat fluxHeat pipeHeat transferGeothermal gradientHeat transfer coefficientOrganic Rankine cycleThermalGeothermal energyThermal energy

Abstract

fetched live from OpenAlex

The Super-long Gravity Heat Pipe (SLGHP) is an efficient geothermal energy utilization technology that can transmit thermal energy by fully utilizing natural temperature differences without external energy input. This study focuses on the high-altitude geothermal environment of Mount Meager, Canada, and employs numerical simulations and dynamic thermal analysis to systematically investigate the thermal transport performance of the SLGHP system under both steady-state and dynamic operating conditions. The study also examines the impact of various structural parameters on the system’s performance. Three-dimensional CFD simulations were conducted to analyze the effects of pipe diameter, length, filling ratio, working fluid selection, and pipe material on the heat transfer efficiency and heat flux distribution of the SLGHP. The results indicate that working fluids such as CO2 and NH3 significantly enhance the heat flux density, while increasing pipe diameter may reduce the amount of liquid retained in the condenser section, thereby affecting condensate return and thermal stability. Furthermore, dynamic thermal analysis using a three-node RC network model simulated the effects of diurnal temperature fluctuations and variations in the convective heat transfer coefficient in the condenser section on system thermal stability. The results show that the condenser heat flux can reach a peak of 5246 W/m2 during the day, while maintaining a range of 2200–2600 W/m2 at night, with the system exhibiting good thermal responsiveness and no significant lag or flow interruption. In addition, based on the thermal output of the SLGHP system and the integration with the Organic Rankine Cycle (ORC) system, the power generation potential analysis indicates that the system, with 100 heat pipes, can provide stable power generation of 50–60 kW. In contrast to previous SLGHP studies focused on generalized modeling, this work introduces a site-specific CFD–RC framework, quantifies structural sensitivity via heat flux indices, and bridges numerical performance with economic feasibility, offering actionable insights for high-altitude deployment. This system has promising practical applications, particularly for providing stable renewable power in remote and cold regions. Future research will focus on field experiments and system optimization to further improve system efficiency and economic viability.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.974
Threshold uncertainty score0.053

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0010.001
Scholarly communication0.0010.000
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.225
Teacher spread0.214 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2025
Admission routes2
Has abstractyes

Explore more

Same venueMiningSame topicThermodynamic and Exergetic Analyses of Power and Cooling SystemsFrench-language works237,207