MétaCan
Menu
Back to cohort
Record W4414160379 · doi:10.1002/mrm.70083

Ex vivo human brain volumetry: Validation of MRI measurements

2025· article· en· W4414160379 on OpenAlexafffund
Amy Gérin‐Lajoie, Walter Adame‐Gonzalez, Éve‐Marie Frigon, Liana Guerra Sanches, Anna Nayouf, Denis Boire, Mahsa Dadar, Josefina Maranzano

Bibliographic record

VenueMagnetic Resonance in Medicine · 2025
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsMontreal Neurological Institute and HospitalMcGill UniversityDouglas Mental Health University InstituteUniversité du Québec à Trois-Rivières
FundersNatural Sciences and Engineering Research Council of CanadaFonds de recherche du Québec – Nature et technologiesCanadian Institutes of Health Research
KeywordsEx vivoHuman brainMagnetic resonance imagingIn vivoSimilarity (geometry)Volume (thermodynamics)

Abstract

fetched live from OpenAlex

Abstract Purpose The volume of in vivo human brains is determined with various MRI measurement tools that have not been assessed against a gold standard. The purpose of this study was to validate the MRI brain volumes by scanning ex vivo, in situ specimens, which allows the extraction of the brain after the scan to compare its volume with the gold‐standard water displacement method (WDM). Methods The 3T MRI T 2 ‐weighted, T 1 ‐weighted, and MP2RAGE images of seven anatomical heads fixed with an alcohol‐formaldehyde solution were acquired. The gray and white matter were assessed using two methods: (i) a manual intensity‐based threshold segmentation using Display (MINC‐ToolKit) and (ii) an automatic deep learning–based segmentation tool ( SynthSeg ). The brains were extracted and their volumes measured with the WDM after the removal of their meninges and a midsagittal cut. Volumes from all methods were compared with the ground truth (WDM volumes) using a repeated‐measures analysis of variance. Results Mean brain volumes, in cubic centimeters, were 1111.14 ± 121.78 for WDM, 1020.29 ± 70.01 for manual T 2 ‐weighted, 1056.29 ± 90.54 for automatic T 2 ‐weighted, 1094.69 ± 100.51 for automatic T 1 ‐weighted, 1066.56 ± 96.52 for automatic magnetization‐prepared 2 rapid gradient‐echo first inversion time, and 1156.18 ± 121.87 for automatic magnetization‐prepared 2 rapid gradient‐echo second inversion time. All volumetry methods were significantly different (F = 17.874; p < 0.001) from the WDM volumes, except the automatic T 1 ‐weighted volumes. Conclusion SynthSeg accurately determined the brain volume in ex vivo, in situ T 1 ‐weighted MRI scans. The results suggested that given the contrast similarity between the ex vivo and in vivo sequences, the brain volumes of clinical studies are most probably sufficiently accurate, with some degree of underestimation depending on the sequence used.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.005
metaresearch head score (Gemma)0.008
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.005
Threshold uncertainty score0.027

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0050.008
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.037
GPT teacher head0.367
Teacher spread0.331 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2025
Admission routes2
Has abstractyes

Explore more

Same venueMagnetic Resonance in MedicineSame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207