MétaCan
Menu
Back to cohort
Record W4414444153 · doi:10.1002/ajum.70026

Development of a Novel Machine Learning Model for Automatic Assessment of Quality of Transvaginal Ultrasound Images From Multi‐Annotator Labels

2025· article· en· W4414444153 on OpenAlexaff
Alison Deslandes, Daniel Petashvili, H. Wang, Gustavo Carnerio, Jodie Avery, G. Condous, Mathew Leonardi, M. Louise Hull, Hsiang‐Ting Chen

Bibliographic record

VenueAustralasian Journal of Ultrasound in Medicine · 2025
Typearticle
Languageen
FieldMedicine
TopicGynecological conditions and treatments
Canadian institutionsMcMaster University
FundersUniversity of AdelaideAustralian Government
KeywordsTransvaginal ultrasoundQuality (philosophy)Quality assessmentUltrasound

Abstract

fetched live from OpenAlex

Objectives: Accurate diagnosis of pathology from ultrasound images is reliant upon images of a suitable diagnostic quality being acquired. This study aimed to create a novel machine learning model to automatically assess transvaginal ultrasound (TVUS) image quality for gynaecological ultrasound. Method: Six imaging professionals (two sonographers, two gynaecological sonologists and two radiologists) assigned a quality score to 150 TVUS images from 50 cases (50 uterus images and 100 ovary images). Images were given a score of 1-4 (1-reject/image inaccurate, 2-poor quality, 3-suboptimal quality or 4-optimal quality). As variation existed between the scores assigned by the labellers, we framed this problem as a multi-annotator noisy label problem. To address this, a new machine learning architecture was developed, combining a weighted ensemble algorithm to estimate consensus labels and a multi-axis vision transformer (MaxViT) to handle noisy labels, improving model accuracy in predicting image quality. Forty cases (120 images) were used for model training, while the remaining 10 cases (30 images) were reserved as a test set for model evaluation. Results: The novel machine learning architecture we created was able to successfully determine image quality with a validation accuracy of 80% and a macro average recall of 77%. This significantly improved upon the 57% accuracy of the baseline machine learning method (ResNet50). The MaxViTs were able to outperform human performance in most cases, with an accuracy of 80% surpassing four of the six human labellers. Conclusions: This novel machine learning model offers an automated method of assessing the quality of TVUS images. The tool has the potential to provide real-time feedback to those performing TVUS, reduce the need for repeated imaging, and improve the diagnosis of gynaecological pathology.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.614
Threshold uncertainty score0.697

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.067
GPT teacher head0.401
Teacher spread0.334 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueAustralasian Journal of Ultrasound in MedicineSame topicGynecological conditions and treatmentsFrench-language works237,207