MétaCan
Menu
Back to cohort
Record W4414741157 · doi:10.1093/clinchem/hvaf086.173

A-179 A Multi-Centre Assessment of Comparability of Hemolysis Indices on Automated Analyzers

2025· article· en· W4414741157 on OpenAlexaffabout
Meshach Asare-Werehene, Saranya Arnoldo, Davor Brinc, Mohamed Bhugun, Blaine Elliot, Lei Fu, Felix Leung, Nurun Muhammed, Annie Ren, Lusia Sepiashvili, Cristiana Stefan, Bo Wan, Paul S. F. Yip

Bibliographic record

VenueClinical Chemistry · 2025
Typearticle
Languageen
FieldMedicine
TopicHeart Rate Variability and Autonomic Control
Canadian institutionsCentre for Addiction and Mental HealthHospital for Sick ChildrenWilliam Osler Health SystemCompute CanadaUniversity Health NetworkHealth Sciences CentreSinai Health SystemSunnybrook Health Science CentreBrampton Civic HospitalMarkham Stouffville HospitalToronto East General HospitalUniversity of Toronto
Fundersnot available
KeywordsHemolysisHemoglobinExternal quality assessmentTurbidimetryAutomated methodComparabilityCoombs test

Abstract

fetched live from OpenAlex

Abstract Background Hemolysis is a prevalent preanalytical issue that compromises quality and patient safety during laboratory testing. It can interfere with sample analysis, leading to inaccurate results, sample rejection, and delayed patient treatment. The International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) has identified hemolysis as a high-priority quality indicator, defined as the rate of samples with hemoglobin (Hgb) above 50 mg/dL (>0.5 g/L). Automated methods have improved hemolysis detection in serum/plasma samples. However, the internal calibration of automated methods for hemoglobin estimation (i.e. Hemolysis index) is usually not verified for accuracy against external standards by the end-user nor standardized across methods. This study aims to address this gap by comparing hemoglobin quantification using the serum indices application on automated chemistry analyzers versus a conventional spectrophotometric method that is validated for plasma free hemoglobin measurement. Methods Plasma samples (n=20) were analyzed at nine laboratories across the Greater Toronto Area in Canada. The plasma free Hgb concentrations in patient samples ranging from 5 to 450 mg/dL (0.05 to 4.50 g/L) were determined with the method of Khan SE et al. (Ann Clin Lab Sci. 1981;11(2):126-31) on Agilent Cary 60 UV/Vis spectrophotometer as the reference. In contrast, estimated Hgb were measured on seven automation systems: Abbott Alinity c, Roche cobas pro (n=2), Roche cobas 8000, Roche cobas 6000, Ortho Vitros 5600 (n=2), Siemens Atellica CH and Beckman Coulter AU680. Method comparison analyses were performed using Passing-Bablok linear regression. Bias was assessed at 50 mg/dL, the IFCC threshold for the hemolysis quality indicator. Subsequently, the percent bias for each automated application was calculated as [(automated Hgb - 50 mg/dL) / 50 mg/dL] x 100. Results All methods’ coefficient of variation (CV) of the hemolysis values for each sample revealed a close agreement among the automated analyzers with a combined CV of 24% and median CV of 8% (range 3% to 73%). However, the biases for Hgb estimates at the IFCC cut-off ranged from 1.4% to 23.0% across the entire range of Hgb levels (5 to 450 mg/dL). The specific biases observed when applying the linear regression for samples with Hgb concentrations <100 mg/dL were: 1.4-10.4% for Roche cobas analyzers, 20.2-21.4% for Ortho Vitros 5600 analyzers, 16.2% for Siemens Atellica CH, 8.0% for Abbott Alinity c and 18.2% for Beckman Coulter AU680, highlighting variations in Hgb estimates among automated analyzers. All automated analyzers demonstrated excellent correlation with the Khan method. The Pearson’s R values ranged from 0.997-0.999 for Hgb concentrations between 5-450 mg/dL, and 0.981-0.999 for Hgb concentrations <100 mg/dL. Conclusion In conclusion, our study revealed excellent correlation among automated analyzers in measuring hemolysis indices, supporting the reliability of these methods. Assessment of hemolysis at the sample level supports the IFCC harmonized quality indicator. However, notable positive biases were observed among some analyzers, which may impact comparisons of hemolysis rates, emphasizing the need for further harmonization among manufacturers.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.150
Threshold uncertainty score0.464

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.044
GPT teacher head0.452
Teacher spread0.408 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2025
Admission routes2
Has abstractyes

Explore more

Same venueClinical ChemistrySame topicHeart Rate Variability and Autonomic ControlFrench-language works237,207