MétaCan
Menu
Back to cohort
Record W4414909352 · doi:10.1016/j.jscai.2025.103946

SCAI Position Statement on Intracardiac Echocardiography to Guide Structural Heart Disease Interventions

2025· article· en· W4414909352 on OpenAlexaff
Mackram F. Eleid, Christine J Chung, Matthew J. Daniels, V. Vivian Dimas, Andrew M. Goldsweig, Harsh Golwala, Eric Horlick, Matthew J. Price, Carlos E. Sánchez, John Saxon, Markus Scherer, Gilbert H.L. Tang, Dee Dee Wang, Omar Khalique

Bibliographic record

VenueJournal of the Society for Cardiovascular Angiography & Interventions · 2025
Typearticle
Languageen
FieldMedicine
TopicCardiac Imaging and Diagnostics
Canadian institutionsToronto General Hospital
FundersPhilips
KeywordsPatent foramen ovalePosition statementPsychological interventionIntracardiac injectionHeart diseaseFluoroscopyStatement (logic)Percutaneous

Abstract

fetched live from OpenAlex

As structural heart disease interventions rapidly evolve, demand for minimally invasive intraprocedural imaging techniques has increased. Intracardiac echocardiography (ICE) has emerged as a valuable imaging modality, offering real-time, high-resolution visualization of cardiac structures without the need for general anesthesia. This position statement from the Society for Cardiovascular Angiography & Interventions outlines the clinical applications, advantages, limitations, and implementation strategies for ICE in guiding transcatheter structural heart disease procedures. The document details standardized ICE imaging protocols and views for interventions involving the mitral, tricuspid, and pulmonary valves, as well as left atrial appendage occlusion atrial septal defect, and patent foramen ovale closure. It emphasizes the importance of operator training, physician workflows, and institutional readiness for successful ICE integration. The statement also advocates for updated reimbursement models that reflect the complexity and value of ICE-guided procedures and calls for further research comparing ICE and transesophageal echocardiography outcomes.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.013
metaresearch head score (Gemma)0.028
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: Not applicable
GenreCandidate signal: Editorial · Consensus signal: none
Teacher disagreement score0.026
Threshold uncertainty score0.068

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0130.028
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0020.003
Bibliometrics0.0020.002
Science and technology studies0.0020.003
Scholarly communication0.0050.002
Open science0.0040.003
Research integrity0.0260.025
Insufficient payload (model declined to judge)0.0120.018

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.331
Teacher spread0.315 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreEditorial

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueJournal of the Society for Cardiovascular Angiography & InterventionsSame topicCardiac Imaging and DiagnosticsFrench-language works237,207