Abstract
Abstract Background This systematic review and meta-analysis aim to evaluate the efficacy and safety of the PAUL ® Glaucoma Implant in reducing intraocular pressure and number of anti-glaucoma medication use in both adult and paediatric populations. Methods A systematic review was conducted following the PRISMA guidelines. The databases PubMed, Ovid-Embase and Scopus were searched to include studies published between January 2017 and September 2025. Studies were stratified by age and risk of bias was assessed using the Newcastle-Ottawa Scale for observational studies and ROBUST-RCT for randomized trials. Primary outcomes were intraocular pressures and number of glaucoma medications at each follow-up visits. Random effects meta-analyses were performed. Secondary outcome was complications. Results Twenty-four studies (twenty adults, four paediatric) comprising 836 eyes were included in our review and meta-analysis. Both adult and paediatric patients showed significant IOP reduction post-surgery, with a mean difference of 17.48 mmHg (95% CI: 14.59, 20.37) and 20.31 mmHg (95% CI: 7.80, 32.82) at 1 week, respectively, and sustained reductions at 12 months. The reduction in glaucoma medications was 79.2% for adults and 71.4% for children at 12 months. Subgroup analyses demonstrated greater IOP reduction in studies conducted in the Middle East. The uses of Mitomycin C did not significantly affect outcomes. Conclusion The PAUL ® glaucoma implant showed significant and sustained IOP reductions with reduced need for glaucoma medications. The PAUL ® glaucoma implant is a promising surgical option for glaucoma management in both adults and children. Further long-term prospective comparative studies are needed to assess long-term efficacies and allow direct comparisons with other glaucoma drainage devices.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.014 | 0.034 |
| Meta-epidemiology (narrow) | 0.003 | 0.001 |
| Meta-epidemiology (broad) | 0.018 | 0.032 |
| Bibliometrics | 0.006 | 0.005 |
| Science and technology studies | 0.001 | 0.001 |
| Scholarly communication | 0.004 | 0.002 |
| Open science | 0.002 | 0.001 |
| Research integrity | 0.002 | 0.002 |
| Insufficient payload (model declined to judge) | 0.005 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".