MétaCan
Menu
Back to cohort
Record W4416133730 · doi:10.3390/mi16111268

Microfluidic Nanosensor for Label-Free Multiplexed Detection of Breast Cancer Biomarkers via Surface-Enhanced Reflective FTIR Spectroscopy Using Thin Gold Films and Antibody-Oriented Gold Nanourchin: Feasibility Study

2025· article· en· W4416133730 on OpenAlexaff
Mohammad E. Khosroshahi, Gayathri Senthilchelvan, Victor Oyebolu

Bibliographic record

VenueMicromachines · 2025
Typearticle
Languageen
FieldBiochemistry, Genetics and Molecular Biology
TopicSpectroscopy Techniques in Biomedical and Chemical Research
Canadian institutionsUniversity of Toronto
Fundersnot available
KeywordsBreast cancerMicrofluidicsFourier transform infrared spectroscopyMultiplexingAnalytical Chemistry (journal)Thin filmRhodamine 6GCancer biomarkersTrastuzumab

Abstract

fetched live from OpenAlex

The simultaneous detection of multiple cancer biomarkers using microfluidic multiplexed immunosensors is gaining significant interest in the field of Point-of-Care diagnostics. This study highlights integrating surface-enhanced infrared Fourier transform (SE-FTIR) with a plasmonic-active nanostructure thin film (PANTF) on a printed circuit board (PCB), housed within a microfluidic device for rapid, non-destructive detection of breast cancer (BC). Detection uses monoclonal antibody (mAb)-functionalized gold nanourchins (GNUs) on dual sensing regions. A total of 12 serum samples (24 data points) were tested for HER-II and CA 15-3. The system demonstrated a SE-FTIR enhancement factor (EF) of ~0.18 × 105 using Rhodamine 6G (R6G). Calibration with HER-II (1–100 ng/mL) and CA 15-3 (10–100 U/mL) showed linear responses (R2 = 0.8 and 0.76, respectively). Measurements of unknowns were performed at 1 µL/min over 68 min, with 43 min for biomarker interaction. SE-FTIR spectra were recorded at active zones and analyzed using SpectraView (SV), a custom Python 3.12-based tool. Data preprocessing included filtering (SciPy’s filtfilt) and baseline correction using the Improved Asymmetric Least Squares (IASLS) algorithm (pybaselines.Whittaker). Fourier cross-correlation (FCC) showed stronger signal consistency for HER-II. Partial Least Squares (PLS) regression, a dimensionality reduction technique, enabled clear discrimination between the samples and types, with classification accuracy reaching 1.0. Cancer staging based on these biomarkers yielded an overall accuracy of 0.54, indicating that classification regardless of biomarker type. Further studies involving larger and more diverse sample sets are critical before any definitive conclusions can be drawn.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.006
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.367
Teacher spread0.353 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueMicromachinesSame topicSpectroscopy Techniques in Biomedical and Chemical ResearchFrench-language works237,207