MétaCan
Menu
Back to cohort
Record W4416276250 · doi:10.2196/35987

Detection of Polyphonic Alarm Sounds From Medical Devices Using Frequency-Enhanced Deep Learning: Simulation Study

2025· article· en· W4416276250 on OpenAlexvenueno aff
Kazumasa Kishimoto, Tadamasa Takemura, Osamu Sugiyama, Ryosuke Kojima, Masahiro Yakami, Goshiro Yamamoto, Tomohiro Kuroda

Bibliographic record

VenueJMIR Medical Informatics · 2025
Typearticle
Languageen
FieldMedicine
TopicPhonocardiography and Auscultation Techniques
Canadian institutionsnot available
Fundersnot available
KeywordsALARMClassifier (UML)False alarmStethoscopePolyphonyPattern recognition (psychology)MicrophoneFeature extraction

Abstract

fetched live from OpenAlex

Background: Although an increasing number of bedside medical devices are equipped with wireless connections for reliable notifications, many nonnetworked devices remain effective at detecting abnormal patient conditions and alerting medical staff through auditory alarms. Staff members, however, can miss these notifications, especially when in distant areas or other private rooms. In contrast, the signal-to-noise ratio of alarm systems for medical devices in the neonatal intensive care unit is 0 dB or higher. A feasible system for automatic sound identification with high accuracy is needed to prevent alarm sounds from being missed by the staff. Objective: The purpose of this study was to design a method for classifying multiple alarm sounds collected with a monaural microphone in a noisy environment. Methods: Features of 7 alarm sounds were extracted using a mel filter bank and incorporated into a classifier using convolutional and recurrent neural networks. To estimate its clinical usefulness, the classifier was evaluated with mixtures of up to 7 alarm sounds and hospital ward noise. Results: The proposed convolutional recurrent neural network model was evaluated using a simulation dataset of 7 alarm sounds mixed with hospital ward noise. At a signal-to-noise ratio of 0 dB, the best-performing model (convolutional neural network 3+bidirectional gate recurrent unit) achieved an event-based F1-score of 0.967, with a precision of 0.944 and a recall of 0.991. When the venous foot pump class was excluded, the classwise recall of the classifier ranged from 0.990 to 1.000. Conclusions: The proposed classifier was found to be highly accurate in detecting alarm sounds. Although the performance of the proposed classifier in a clinical environment can be improved, the classifier could be incorporated into an alarm sound detection system. The classifier, combined with network connectivity, could improve the notification of abnormal status detected by unconnected medical devices.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.012
Threshold uncertainty score0.024

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.342
Teacher spread0.327 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueJMIR Medical InformaticsSame topicPhonocardiography and Auscultation TechniquesFrench-language works237,207