MétaCan
Menu
Back to cohort
Record W4416817371 · doi:10.61558/2993-074x.3572

Development of a Digestion Procedure Using Fe<sup>2+</sup> Ions for Electrochemical Detection of MnO<sub>2</sub> Particles in Drinking Water

2025· article· en· W4416817371 on OpenAlexafffundabout
Kayla Elliott, Sarah Jane Payne, Zhe She

Bibliographic record

VenueDian hua xue/Dian huaxue · 2025
Typearticle
Languageen
FieldChemistry
TopicElectrochemical Analysis and Applications
Canadian institutionsQueen's University
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsDigestion (alchemy)Detection limitManganeseParticulatesReproducibilityStoichiometryElectrochemistry

Abstract

fetched live from OpenAlex

Developing methods for detection contaminants in drinking water is essential to ensuring that safe and acceptable quality drinking water is delivered to consumers. While manganese (Mn) was previously known only as a mere aesthetic issue, recent epidemiological data has shown to have negative neurological effects on humans, especially on children, prompting new health-based guidelines by Health Canada and the World Health Organization. In drinking water, Mn exists predominantly as Mn(II) and Mn(IV), and is regulated based on total Mn levels. Interestingly, measurement of Mn particulate using electroanalytical methods has not yet been reported in the literature. Herein, a digestion procedure for insoluble manganese dioxide (MnO2) using ferrous (Fe2+) ions was optimized in preparation for Mn detection by cyclic voltammetry (CV). Digestion conditions including concentration of Fe2+ ions, pH and digestion time were explored and optimized. Digestion of MnO2 was found to be successful in both perfect and imperfect stoichiometric ratios; however, digestion was shown to be most effective in perfect stoichiometric conditions. CV proved to be an effective technique for the detection of different particulate Mn concentrations with good reproducibility using glassy carbon electrodes. According to the CV data, the detection limits of 0.3 mmol·L–1 and 0.1 mmol·L–1 for MnO2 were determined after the digestion time of 4.5 h and 24 h, respectively. The digestion method, in addition to CV detection, was found to be impacted by the presences of Cu2+ and Fe3+ ions.This interference suggests that this method may offer value as a multi-plexed technique. The Mn reduction signal was found to be enhanced in the presence of Mn2+, indicating that this method has the potential to be used to detect soluble and insoluble Mn species simultaneously. These digestion and detection methods are simple and reproducible methods which introduce the opportunity for total Mn detection in drinking water.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.237
Teacher spread0.227 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2025
Admission routes3
Has abstractyes

Explore more

Same venueDian hua xue/Dian huaxueSame topicElectrochemical Analysis and ApplicationsFrench-language works237,207