MétaCan
Menu
Back to cohort
Record W4417209973 · doi:10.1088/1361-6560/ae2b4a

A compact depth-of-interaction time-of-flight detector panel dedicated for organ-specific PET scanner

2025· article· en· W4417209973 on OpenAlexaff
Mehdi Amini, Abdollah Saberi, K. Doroud, Hossein Arabi, Habib Zaidi

Bibliographic record

VenuePhysics in Medicine and Biology · 2025
Typearticle
Languageen
FieldPhysics and Astronomy
TopicRadiation Detection and Scintillator Technologies
Canadian institutionsSciencetech (Canada)
FundersEurostarsHôpitaux Universitaires de GenèveEuropean Commission
KeywordsDetectorCalibrationScannerEnergy (signal processing)Axial symmetryImage resolutionCrystal (programming language)Photon counting

Abstract

fetched live from OpenAlex

Abstract Objective. Dedicated positron emission tomography (PET) scanners designed for specific organs or clinical applications require compact detector modules with high depth-of-interaction (DOI) and time-of-flight (TOF) capabilities. In this study, we present the design and evaluation of a compact, ready-to-use PET detector panel optimized for such scanners. Approach. The panel, measuring 98.4 × 104.2 mm 2 , comprises a 4 × 3 array of four-layer, dual-readout detector towers. Detector towers operate in side-irradiation configuration, thereby enabling DOI measurement across the layers, while axial positioning is derived from the dual-ended readout. Each tower is built from a 8 × 4 × 1 array of 2.05 × 4.4 × 30 mm 3 Lutetium Fine Silicate (LFS) crystals, axially coupled to strip-shaped multi-pixel photon counters, with both ends of each strip read out through independent electronic channels. A high-speed electronic readout system based on the picoTDC application-specific integrated circuit was developed to enable precise timing and amplitude measurements. Calibration and performance evaluations were conducted under realistic and scaled conditions. A full-range energy calibration was performed at crystal-level using multiple gamma-emitting isotopes to linearize the detector’s response and extract energy resolution. Calibration for axial-positioning along the length of the crystals (between two readout ends) was achieved through a simple flood irradiation-based method, eliminating the need for point-specific irradiations. Main results. Average energy resolutions of 14.2%, 14.3%, 15.3%, and 15.4% were achieved for crystals in layers 1 through 4, respectively. DOI and transaxially positioning steps of 4.4 mm, and 2.05 mm, respectively are obtainable based on layer and crystal pitch. The measured axial spatial resolutions were 3.78 mm, 3.84 mm, 4.01 mm, and 4.78 mm full-width-half-maximum for layers 1 through 4, respectively. TOF resolution averaged 196 ± 7 ps for layer 1–1 pair, gradually degrading to 220 ± 17 ps for layer 4–4 pairs. Significance. Balancing performance, scalability, and manufacturability, this detector panel offers a practical and easily calibratable solution for next-generation organ-dedicated PET systems with DOI-TOF capability.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.286
Threshold uncertainty score0.290

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.141
GPT teacher head0.372
Teacher spread0.230 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2025
Admission routes1
Has abstractyes

Explore more

Same venuePhysics in Medicine and BiologySame topicRadiation Detection and Scintillator TechnologiesFrench-language works237,207