MétaCan
Menu
Back to cohort
Record W4417520722 · doi:10.1016/j.ejmp.2025.105693

Fast personalized CT dose calculations with GPUMCD

2025· article· en· W4417520722 on OpenAlexafffund
Ronan Lefol, Yannick Lemaréchal, Alexandre Sagona, J.-F. Boivin, Philippe Joubert, Philippe Després

Bibliographic record

VenuePhysica Medica · 2025
Typearticle
Languageen
FieldMedicine
TopicRadiation Dose and Imaging
Canadian institutionsInstitut universitaire de cardiologie et de pneumologie de QuébecCentre hospitalier de l'Université LavalUniversité Laval
FundersCanadian Cancer SocietyMcGill University Health CentreQuébec Consortium for Drug DiscoveryFonds de Recherche du Québec - SantéFondation Institut Universitaire de Cardiologie et de Pneumologie de QuébecInstitut universitaire de cardiologie et de pneumologie de Québec, Université LavalAstraZenecaNatural Sciences and Engineering Research Council of CanadaFonds de recherche du QuébecPfizer
KeywordsDosimetryPipeline (software)Medical imagingComputed tomographyRadiation dose

Abstract

fetched live from OpenAlex

PURPOSE: The continuous increase of population dose due to ever-rising Computed Tomography (CT) examinations has called for more personalized dose estimations in medical imaging - a far from trivial task. This study aims to demonstrate a GPU-enabled pipeline combining automatic segmentation with GPU Monte Carlo Dose (GPUMCD) simulations to provide patient-specific dose-to-organ CT dosimetry reports using existing patient CT images. METHODS: A dynamic representation of the CT imaging process was reproduced within GPUMCD using information in DICOM headers, complemented by in-house exposure measurements, and validated in homogeneous and anthropomorphic phantoms. A dose pipeline was implemented using GPUMCD and a pre-trained open-source nnU-net model (TotalSegmentator). Dose-to-organ dosimetry was obtained for images from a lung cancer screening program and stored in DICOM-compliant Structured Reports. RESULTS: GPUMCD calculated dose values were within 5.5% of measurements for all phantoms and investigated conditions. Utilizing one A100-SXM4-40GB GPU, the average pipeline runtime was 6 min and 06 s per CT study. The GPU-driven simulation and segmentation operation took 46% (2 min and 7 s) of the total runtime, and data processing (file reading, conversion, and writing) occupied the remaining 54%. CONCLUSION: This work demonstrates the ability to generate patient-specific three-dimensional dose distributions in CT within a few seconds and the subsequent feasibility of performing fully automated mass personalized dose-to-organ calculations. The pipeline ingests and produces DICOM-compliant data compatible with clinical and research environments, enabling routine imaging dosimetry and large-scale retroactive dosimetry studies.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.464
Threshold uncertainty score0.309

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.293
Teacher spread0.283 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2025
Admission routes2
Has abstractyes

Explore more

Same venuePhysica MedicaSame topicRadiation Dose and ImagingFrench-language works237,207