MétaCan
Menu
Back to cohort
Record W44257826

Recombinant single chain cardiac troponin I-C polypeptides: superior calibration and control materials for cardiac troponin I immunoassays.

2001· article· en· W44257826 on OpenAlexaff
S Liu, M Y Zhang, Qianli Song, M Ling, Lilly Kadijevic, Qi Shi

Bibliographic record

VenuePubMed · 2001
Typearticle
Languageen
FieldBiochemistry, Genetics and Molecular Biology
TopicAdvanced Biosensing Techniques and Applications
Canadian institutionsCerebral Diagnostics (Canada)
Fundersnot available
KeywordsTroponinTroponin ITroponin TTroponin CTroponin complexChemistryProteolysisRecombinant DNAChromatographyBiochemistryMedicineCardiologyEnzyme
DOInot available

Abstract

fetched live from OpenAlex

There has been a need to create stable and reproducible calibration and control materials for cardiac troponin I assays. Free troponin I, native or recombinant, has been known to be unstable, while troponin CI complex can be easily dissociated in low concentrations or in the presence of chelating agents. In order to overcome these difficulties, two single chain troponin I-C polypeptides have been engineered and expressed separately in Escherichia coli. One consists of a full-length of human cardiac troponin I and C, termed as ScTnI-C and the other consists of a stable fragment (aa28-110) of human cardiac troponin I and a full-length troponin C, termed as ScTnI-C-2. Both ScTnI-C and ScTnI-C-2 were purified to homogeneity by affinity chromatography using anti-cTnI monoclonal antibodies. ScTnI-C and ScTnI-C-2 have apparent molecular weights of 45 kD and 30 kD by SDS-PAGE, respectively. Stability studies by Stratus showed that ScTn I-C and ScTnI-C-2 were stable for 4 months at 2-8 degrees C and at least one year at -20 degrees C. When incubated in human serum at 37 degrees C, ScTnI-C-2 was more resistant to proteolysis than ScTnI-C. ScTnI-C can be recognized by all commercial TnI immunoassays with excellent activity. ScTnI-C-2 can be recognized by all immunoassays that target the stable region of cardiac troponin I. Judging by their performances, ScTnI-C and ScTnI-C-2 are both superior materials to be used as calibrators and controls in clinical laboratories.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.005
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.005
Threshold uncertainty score0.026

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0050.004
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.223
Teacher spread0.212 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2001
Admission routes1
Has abstractyes

Explore more

Same venuePubMedSame topicAdvanced Biosensing Techniques and ApplicationsFrench-language works237,207