MétaCan
Menu
Back to cohort
Record W54251026

Robotic pyeloplasty: experience with three robotic platforms.

2007· article· en· W54251026 on OpenAlexaff
Christopher Nguan, Kevin Kwan, Mohammed Al Omar, Kenneth A Beasley, Patrick P W Luke

Bibliographic record

VenuePubMed · 2007
Typearticle
Languageen
FieldMedicine
TopicPediatric Urology and Nephrology Studies
Canadian institutionsLondon Health Sciences Centre
Fundersnot available
KeywordsPyeloplastyMedicineAnastomosisSurgeryZEUS (particle detector)Da Vinci Surgical SystemLaparoscopyRobotic surgeryInternal medicineHydronephrosisUrinary system
DOInot available

Abstract

fetched live from OpenAlex

PURPOSE: Laparoscopic pyeloplasty is a technically challenging procedure. Currently, several robotic surgical systems exist to overcome laparoscopic technical challenges confronted during pyeloplasty. We present a clinical comparison between three robotic surgical systems (Aesop, Zeus and da Vinci) in assisting laparoscopic pyeloplasty procedures. METHODS: From January 2002 to August 2005, 32 dismembered laparoscopic pyeloplasties were performed using three robotic surgical systems. The results of the initial six, five and nine laparoscopic robotic pyeloplasty procedures performed using the Aesop, Zeus and da Vinci platforms were compared. Data relating to the subsequent 12 pyeloplasties using the da Vinci system were also analyzed. RESULTS: The da Vinci robot required significantly more time to set up initially than the Aesop platform (12.5 min versus 39 min, p < 0.05) but the time was similar to that for the Zeus robot. Despite the longer setup time, laparoscopic robotic pyeloplasties performed using the da Vinci robot required 168 min and 35 min for operating time and anastomotic time, respectively. This was significantly faster than that for Aesop (262 min and 75 min) and Zeus (225 min and 71 min) robots (p < 0.05). There were no intra-operative complications. There was only one postoperative complication in the Zeus group involving a delayed urine leak. Narcotic requirements were low and duration of hospital stay was short for all patients. CONCLUSIONS: We show that not all advanced robotic platforms are equal. In this study, procedures performed using the da Vinci robotic system resulted in decreased anastomotic and operating times. With emerging surgical technologies, the role of the robot in surgery continues to be defined.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.027
Threshold uncertainty score0.489

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.027
GPT teacher head0.238
Teacher spread0.210 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations13
Published2007
Admission routes1
Has abstractyes

Explore more

Same venuePubMedSame topicPediatric Urology and Nephrology StudiesFrench-language works237,207