MétaCan
Menu
Back to cohort
Record W623420803

Torsion in Helically Reinforced Prestressed Concrete Poles

2008· dissertation· en· W623420803 on OpenAlexaboutno aff
Michael Kuebler

Bibliographic record

VenueUWSpace (University of Waterloo) · 2008
Typedissertation
Languageen
FieldEngineering
TopicStructural Behavior of Reinforced Concrete
Canadian institutionsnot available
Fundersnot available
KeywordsStructural engineeringTorsion (gastropod)Prestressed concreteReinforced concreteEngineeringGeotechnical engineeringMaterials scienceGeology
DOInot available

Abstract

fetched live from OpenAlex

Reinforced concrete poles are commonly used as street lighting and electrical transmission poles. Typical concrete lighting poles experience very little load due to torsion. The governing design loads are typically bending moments as a result of wind on the arms, fixtures, and the pole itself. The Canadian pole standard, CSA A14-07 relates the helical reinforcing to the torsion capacity of concrete poles. This issue and the spacing of the helical reinforcing elements are investigated. \nBased on the ultimate transverse loading classification system in the Canadian standard, the code provides a table with empirically derived minimum helical reinforcing amounts that vary depending on: 1) the pole class and 2) distance from the tip of the pole. Research into the minimum helical reinforcing requirements in the Canadian code has determined that the values were chosen empirically based on manufacturer’s testing. The CSA standard recommends two methods for the placement of the helical reinforcing: either all the required helical reinforcing is wound in one direction or an overlapping system is used where half of the required reinforcing is wound in each direction. From a production standpoint, the process of placing and tying this helical steel is time consuming and an improved method of reinforcement is desirable. Whether the double helix method of placement produces stronger poles in torsion than the single helix method is unknown. The objectives of the research are to analyze the Canadian code (CSA A14-07) requirements for minimum helical reinforcement and determine if the Canadian requirements are adequate. The helical reinforcement spacing requirements and the effect of spacing and direction of the helical reinforcing on the torsional capacity of a pole is also analyzed. Double helix and single helix reinforcement methods are compared to determine if there is a difference between the two methods of reinforcement. \nThe Canadian pole standard (CSA A14-07) is analyzed and compared to the American and German standards. It was determined that the complex Canadian code provides more conservative spacing requirements than the American and German codes however the spacing requirements are based on empirical results alone. The rationale behind the Canadian code requirements is unknown. \nA testing program was developed to analyze the spacing requirements in the CSA A14-07 code. Fourteen specimens were produced with different helical reinforcing amounts: no reinforcement, single and double helical spaced CSA A14-07 designed reinforcement, and single helical specimens with twice the designed spacing values. Two specimens were produced based on the single helical reinforcement spacing. One specimen was produced with helical reinforcement wound in the clockwise direction and another with helical reinforcement in the counter clockwise direction. All specimens were tested under a counter clockwise torsional load. The clockwise specimens demonstrated the response of prestressed concrete poles with effective helical reinforcement whereas the counter clockwise reinforced specimens represented theoretically ineffective reinforcement. Two tip sizes were produced and tested: 165 mm and 210 mm. \nA sudden, brittle failure was noted for all specimens tested. The helical reinforcement provided no post-cracking ductility. It was determined that the spacing and direction of the helical reinforcement had little effect on the torsional capacity of the pole. Variable and scattered test results were observed. Predictions of the cracking torque based on the ACI 318-05, CSA A23.3-04 and Eurocode 2 all proved to be unconservative. Strut and tie modelling of the prestressing transfer zone suggested that the spacing of the helical steel be 40 mm for the 165 mm specimens and 53 mm for the 210 mm specimens. Based on the results of the strut and tie modelling, it is likely that the variability and scatter in the test results is due to pre-cracking of the specimens. All the 165 mm specimens and the large spaced 210 mm specimens were inadequately reinforced in the transfer zone. The degree of pre-cracking in the specimen likely causes the torsional capacity of the pole to vary. \nThe strut and tie model results suggest that the requirements of the Canadian code can be simplified and rationalized. Similar to the American spacing requirements of 25 mm in the prestressing transfer zone, a spacing of 30 mm to 50 mm is recommended dependent on the pole tip size. Proper concrete mixes, adequate concrete strengths, prestressing levels, and wall thickness should be emphasized in the torsional CSA A14-07 design requirements since all have a large impact on the torsional capacity of prestressed concrete poles. \nRecommendations and future work are suggested to conclusively determine if direction and spacing have an effect on torsional capacity or to determine the factors causing the scatter in the results. The performance of prestressed concrete poles reinforced using the suggestions presented should also be further investigated. Improving the ability to predict the cracking torque based on the codes or reducing the scatter in the test results should also be studied.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.007
Threshold uncertainty score0.014

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.186
Teacher spread0.179 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2008
Admission routes1
Has abstractyes

Explore more

Same venueUWSpace (University of Waterloo)Same topicStructural Behavior of Reinforced ConcreteFrench-language works237,207