MétaCan
Menu
Back to cohort
Record W66240855 · doi:10.1016/j.jcmg.2013.03.008

T1 Mapping for the Diagnosis of Acute Myocarditis Using CMR

2013· article· en· W66240855 on OpenAlexaff
Vanessa M. Ferreira, Stefan K. Piechnik, Erica Dall’Armellina, Theodoros D. Karamitsos, Jane M Francis, Ntobeko Ntusi, Cameron J. Holloway, Robin P. Choudhury, Attila Kardos, Matthew D. Robson, Matthias G. Friedrich, Stefan Neubauer

Bibliographic record

VenueJACC. Cardiovascular imaging · 2013
Typearticle
Languageen
FieldMedicine
TopicViral Infections and Immunology Research
Canadian institutionsLibin Cardiovascular Institute of AlbertaUniversité de Montréal
FundersNational Institute for Health and Care ResearchWellcome Trust
KeywordsMedicineMyocarditisAcute myocarditisMagnetic resonance imagingCardiologyInternal medicineCardiac magnetic resonanceRadiologyNuclear medicine

Abstract

fetched live from OpenAlex

OBJECTIVES: This study sought to test the diagnostic performance of native T1 mapping in acute myocarditis compared with cardiac magnetic resonance (CMR) techniques such as dark-blood T2-weighted (T2W)-CMR, bright-blood T2W-CMR, and late gadolinium enhancement (LGE) imaging. BACKGROUND: The diagnosis of acute myocarditis on CMR often requires multiple techniques, including T2W, early gadolinium enhancement, and LGE imaging. Novel techniques such as T1 mapping and bright-blood T2W-CMR are also sensitive to changes in free water content. We hypothesized that these techniques can serve as new and potentially superior diagnostic criteria for myocarditis. METHODS: We investigated 50 patients with suspected acute myocarditis (age 42 ± 16 years; 22% women) and 45 controls (age 42 ± 14 years; 22% women). CMR at 1.5-T (median 3 days from presentation) included: 1) dark-blood T2W-CMR (short-tau inversion recovery); 2) bright-blood T2W-CMR (acquisition for cardiac unified T2 edema); 3) native T1 mapping (shortened modified look-locker inversion recovery); and 4) LGE. Image analysis included: 1) global T2 signal intensity ratio of myocardium compared with skeletal muscle; 2) myocardial T1 relaxation times; and 3) areas of LGE. RESULTS: Compared with controls, patients had significantly higher global T2 signal intensity ratios by dark-blood T2W-CMR (1.73 ± 0.27 vs. 1.56 ± 0.15, p < 0.01), bright-blood T2W-CMR (2.02 ± 0.33 vs. 1.84 ± 0.17, p < 0.01), and mean myocardial T1 (1,010 ± 65 ms vs. 941 ± 18 ms, p < 0.01). Receiver-operating characteristic analysis showed clear differences in diagnostic performance. The areas under the curve for each method were: T1 mapping (0.95), LGE (0.96), dark-blood T2 (0.78), and bright-blood T2 (0.76). A T1 cutoff of 990 ms had a sensitivity, specificity, and diagnostic accuracy of 90%, 91%, and 91%, respectively. CONCLUSIONS: Native T1 mapping as a novel criterion for the detection of acute myocarditis showed excellent and superior diagnostic performance compared with T2W-CMR. It also has a higher sensitivity compared with T2W and LGE techniques, which may be especially useful in detecting subtle focal disease and when gadolinium contrast imaging is not feasible.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.006
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.016

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.006
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.040
GPT teacher head0.305
Teacher spread0.265 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations382
Published2013
Admission routes1
Has abstractyes

Explore more

Same venueJACC. Cardiovascular imagingSame topicViral Infections and Immunology ResearchFrench-language works237,207