Design of Self-Tuning Regulator Adaptive Cascade Control for Power Factor Correction in Boost Rectifier
Bibliographic record
Abstract
The widespread use of electronic devices in various applications has led to increased harmonic distortion in power lines, resulting in a decreased power factor and reduced overall power quality. Voltage rectifiers connected to the line can be significant sources of this distortion. To mitigate these effects, it is crucial to enhance the power factor and minimize line current harmonics. This study employs a cascade-controlled boost converter for power factor correction, leveraging both voltage and current regulation. By integrating a self-tuning regulator (STR) adaptive controller with online identification within each control loop, this approach dynamically adjusts to fluctuations in current consumption over time. The proposed method effectively reduces Total Harmonic Distortion (THD) and improves power factor, contributing to more efficient and reliable power systems.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.002 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.000 |
| Bibliometrics | 0.001 | 0.001 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.002 |
| Open science | 0.001 | 0.000 |
| Research integrity | 0.000 | 0.001 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".