MétaCan
Menu
Back to cohort
Record W6903009111 · doi:10.7939/r3-x26k-gh66

Development of a Detailed Finite Element Model of the BIPED and Verification of Fidelity in Two Cases of Blunt Impact

2023· dissertation· en· W6903009111 on OpenAlexaboutno aff

Bibliographic record

VenueUniversity of Alberta Library · 2023
Typedissertation
Languageen
FieldMedicine
TopicAutomotive and Human Injury Biomechanics
Canadian institutionsnot available
Fundersnot available
KeywordsFinite element methodHead (geology)Displacement (psychology)Experimental dataSensitivity (control systems)Human headDevelopment (topology)Pressure measurement

Abstract

fetched live from OpenAlex

Physical surrogates of the human head are commonly used to model cranial impacts and assess head injuries. The Brain Injury Protection Evaluation Device (BIPED mk2) is a head form that contains a brain simulant, fluid layer, connective membranes, a skull, and a skin layer and can measure kinematics, intracranial pressures, and strains. Finite element (FE) models can play a significant role in the development of new head form digital design iterations that better mimic the biological response of the head during impact by allowing researchers to modify material properties and geometries without fully redesigning and manufacturing the head form. This requires digitizing precise geometry, developing accurate material models and implementing realistic boundary conditions within the model. This study aims to create a digital model of the BIPED, perform a comparison of the model using supplied experimental data for both node displacement and pressure, complete a sensitivity study that ascertains whether the location of experimentally instrumented locations affected model outputs, and determine the effectiveness of experimental pressure sensors at capturing the coup and contrecoup phenomenon. The model was developed in ABAQUS based on Computer-Aided Design (CAD) geometry supplied by Defense Research and Development Canada (DRDC). Two different types of BIPED experimental test data were simulated with the developed finite element model: displacement tests and pressure tests. Pressure and displacement time series responses were compared to the experimental data using CORrelation and Analysis (CORA). The CORA values for the pressure comparison indicate an excellent correlation (>0.7) at the front sensor, while the back sensor was not considered just below a good correlation (<0.5). CORA ratings for the x (anterior-posterior) and z (superior-inferior) displacements of the 18 nodes tested resulted in a 0.554 average value, indicating a good correlation to the experimental data (> 0.5). Model simulations and helmeted experimental impacts were used to understand the sensitivity of the pressure sensor locations within the BIPED. Kinematics from helmeted drop tower experiments were input into the model to determine the sensitivity of the simulation output location. One element removed (approximately 5 mm) in the x (anterior-posterior), y (medial-lateral), and z (superior-inferior) directions were compared to the center element (sensor location). A directional bias was observed in the direction parallel to impact, with the average percent difference from the center element being 11.7%. Nodal percent differences were then compared for the displacement tests in the x and z directions. This resulted in a 14.6%, unbiased, percent difference. These large sensitivities indicate that pressure and displacements in a finite element model brain are highly dependant on location. The helmeted impacts were used to determine the effectiveness of the pressure sensor locations at correctly identifying the coup and contrecoup pressures. This was done by extracting the pressure gradient along the line of impact and comparing the values that the sensor locations read. It was determined that the sensors successfully characterised the coup and contrecoup pressure for impacts along its line of action but failed to do so for off-line impacts. Based upon CORA scores, this study demonstrates successful development of a digital twin FE model for the BIPED head surrogate and comparison against experimental pressure and nodal displacement data with both kinematic and force inputs. Additionally, this study underlines the importance of knowing the correct location of the physical sensors while choosing output locations in finite element simulations. Lastly, this thesis helps identify that the locations chosen for pressure sensors in physical surrogate models adequately represented the coup and contrecoup pressures.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.008
Threshold uncertainty score0.016

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0010.000
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0040.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.025
GPT teacher head0.265
Teacher spread0.240 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueUniversity of Alberta LibrarySame topicAutomotive and Human Injury BiomechanicsFrench-language works237,207