Removal and Recycling of Antimony in a Gold Concentrate
Bibliographic record
Abstract
In this article, antimony was removed from the gold concentratebythe alkali leaching method, and then the recovery of antimony solution was also studied. The test used NaOH-Na2S process to remove in gold concentrate, which achieved the purpose of reducing antimony in the gold concentrate, and determined the best process parameters for the antimony removal.The addition amount of Na2S is more than 1.8 times the theoretical amount, the temperature is 80 ℃, the NaOH concentration is 16 g/L, the liquid to solid ratio is 5∶1, the time is 60 min, and the removal rate can reach more than 98% at the optimal process conditions. Antimony can be recovered by neutralizing precipitation method, oxygen method can also be used from the antimony solution to obtain qualified antimony salt products, and the antimony content can reach more than 49%.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.000 |
| Bibliometrics | 0.001 | 0.000 |
| Science and technology studies | 0.001 | 0.000 |
| Scholarly communication | 0.001 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.001 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".