MétaCan
Menu
← Back to cohort
Record W6996056650

Quantification des immunoglobulines A par résonance des plasmons de surface pour identifier les individus IgA-déficients

2023· dissertation· fr· W6996056650 on OpenAlexfundaboutno aff

Bibliographic record

VenuePapyrus : Institutional Repository (Université de Montréal) · 2023
Typedissertation
Languagefr
FieldMedicine
TopicMonoclonal and Polyclonal Antibodies Research
Canadian institutionsnot available
FundersUniversité de MontréalMitacs
KeywordsAgrégationSurface plasmonBlood protein electrophoresis
DOInot available

Abstract

fetched live from OpenAlex

Le but de ce projet, en collaboration avec Héma-Québec, était de développer une méthode point de service (POC) pour la quantification des immunoglobulines A (IgA) dans un petit volume de plasma humain. Les IgA jouent un rôle important au niveau de notre système immunitaire, surtout au niveau des bio fluides sur les muqueuses comme la salive. On peut les retrouver normalement dans le plasma à des concentrations plus grandes que 2000 ng/mL pour la majorité des gens. Dans le cas d’une personne immunosupprimée, une concentration plus basse que 500 ng/mL est observée. La déficience en IgA est souvent associée à des maladies auto-immunes comme la maladie de Crohn. Ces individus peuvent éprouver un choc anaphylactique à la suite d’une transfusion de sang, ce qui nous motive à utiliser la résonance des plasmons de surface (SPR) sur place à des collectes de sang et dans les milieux hospitaliers. Pour réaliser ce capteur d’immunodéficience en IgA, un anticorps primaire spécifique aux IgA fut lié à un peptide formant une monocouche auto-assemblée sur une surface d’or du capteur SPR. Un deuxième anticorps a été utilisé pour quantifier spécifiquement cet analyte dans une matrice humaine complexe. Plusieurs étapes ont été optimisées pour obtenir une limite de détection basse, soit l’étape d’immobilisation de l’anticorps de capture, le type d’anticorps, le pH pour l’immobilisation, la détection secondaire, la validation dans différentes matrices biologiques, parmi d’autres. Le capteur a été validé avec quelques échantillons cliniques et la réponse SPR fut comparée avec ELISA. Ainsi, nous anticipons que cette méthode pourrait être utile à des collectes de sang pour assurer les réserves de sang déficient en IgA.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.022
Threshold uncertainty score0.043

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0020.001
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.025
GPT teacher head0.251
Teacher spread0.226 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2023
Admission routes2
Has abstractyes

Explore more

Same venuePapyrus : Institutional Repository (Université de Montréal)→Same topicMonoclonal and Polyclonal Antibodies Research→French-language works237,207→