Fire and steel stud walls : stud spacing and type of insulation are just two of the factors that will affect how long a typical residential loadbearing steel stud wall assembly can last in a fire
Bibliographic record
Abstract
Steel framing has been widely used in residential buildings in recent years. Loadbearing steel and wall assemblies form part of steel framing and are often used as party walls in townhouses and as party and corridor walls in multi-unit low-rise construction. Consequently, in Canada, they are required to meet fire resistance requirements.Because there is very limited information on the fire resistance of load-bearing steel and wall assemblies in the literature and in building codes, the National Research Council of Canada's Institute for Research in Construction conducted a series of fire resistance experiments on full-scale wall assemblies in an attempt to generate data. The tests were part of a major collaborative research project initiated with nine industry partners to develop fire resistance ratings for these and various other types of wall assemblies.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.002 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.001 | 0.001 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.005 | 0.001 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".