Model-Based Enhanced Operation of Building Convective Heating Systems and Active Thermal Storage
Bibliographic record
Abstract
This thesis presents an experimental and theoretical study of a reduced-order modelling methodology and dynamic response of convectively heated buildings and active thermal storage. A methodology was developed for the generation of control-oriented building models which can be used within model predictive control (MPC) or other model-based control strategies to satisfy occupant comfort and improve building-grid interaction. A methodology to identify and evaluate MPC strategies is presented to improve a building's energy flexibility. There is an emphasis on modelling building thermal mass and a dedicated thermal storage device. The two applications for reduced-order thermal modelling (buildings and dedicated active thermal energy storage devices) require different modelling approaches for control applications. Several case studies are introduced and are typical Quebec construction with convective-based heating systems: a detached low-mass house, a low-mass retail building, and a warehouse (with active thermal storage device). \n \nThe residential building study outlined a methodology for multi-level control-oriented modelling with several zones and multiple floors. This multi-level approach allows the user to “zoom in and out” so that models at each control level remain manageable. In the second case study, implementation of MPC was presented for a conventional bank building to reduce the yearly utility bill and avoid the summer peak load penalty. A cost savings of 25% on the yearly electric utility bill and a peak power reduction of 38% were achieved. With the new optimized operation, the cost per square meter for the bank would decrease from $30.19/m2 to $22.57/m2, or a yearly savings of $7.62/m2. \n \nThe last case study comprises a 1650 m2 warehouse equipped with a dedicated active high-temperature thermal energy storage device. A methodology was presented for the development and analysis of control-oriented models for enhanced operation of the electric thermal storage device. The goal was to maximize the building energy flexibility the building could provide to the grid by evaluating the Building Energy Flexibility Index (BEFI). A BEFI of 55% to 100% was achieved. The average demand during the critical times was reduced between 36 kW and 65 kW and the utility cost to the customer can be reduced by 12-30%.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.001 | 0.000 |
| Open science | 0.001 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.002 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".