MétaCan
Menu
Back to cohort
Record W7016098807

Vision Performance of a 3-Zone Progressive™ Design Kalifilcon A Silicone Hydrogel Multifocal Contact Lens is Not Influenced by Pupil Size: Findings from a Multicenter Clinical Study

2025· article· en· W7016098807 on OpenAlexaff

Bibliographic record

VenueDOAJ (DOAJ: Directory of Open Access Journals) · 2025
Typearticle
Languageen
FieldMedicine
TopicOcular Surface and Contact Lens
Canadian institutionsGlobal Affairs Canada
Fundersnot available
KeywordsPupilContact lensPupil sizePupil diameterClinical studyLuminanceStatistical analysisVisual acuity
DOInot available

Abstract

fetched live from OpenAlex

Nitasha R Phatak,1 William Reindel,1 Marjorie J Rah,1 Howard Proskin,2 Kerry Giedd,3 Andrew D Pucker4 1Bausch + Lomb Incorporated, Rochester, NY, USA; 2Howard M. Proskin & Associates, Rochester, NY, USA; 3Eola Eyes, Orlando, FL, USA; 4Lexitas Pharma Services, Inc., Durham, NC, USACorrespondence: Marjorie J Rah, Bausch + Lomb Incorporated, 1400 N. Goodman St, Rochester, NY, 14609, USA, Tel +1 585-413-6397, Email marjorie.rah@bausch.comPurpose: Factors including age, refractive error, and luminance can affect pupil size and may influence the performance of multifocal contact lenses (MFCLs). This post-hoc analysis aimed to investigate correlations between pupil size and vision performance of a 3-Zone Progressive™ design, daily disposable silicone hydrogel (kalifilcon A) MFCL.Methods: Habitual MFCL wearers aged ≥ 40 years were enrolled in a 3-week, single-arm, bilateral, open-label study to assess near, intermediate, and distant vision performance. Pupil sizes were recorded at dispensing, along with binocular high-contrast visual acuity (VA) by logMAR. VA was assessed at 1- and 3-weeks’ follow-up for distance, intermediate, and near vision, and participants rated vision performance using a 0– 100 scale (100=most favorable) at both these follow-ups. Responses with score ≥ 50 were considered favorable. Pearson correlation coefficient (r) was used to determine the correlation significance.Results: Pupil size ranged from 2.0 mm to 7.0 mm. Mean logMAR VA was − 0.009, 0.046, and 0.114 (1 week), and − 0.012, 0.046, and 0.115 (3 weeks) for distance, intermediate, and near vision, respectively. Statistical analysis of the VA distribution found no significant correlation between VA and pupil size after 1 week of MFCL wear for distance or near vision (r2=0.003 and 0.006, respectively; both p≥ 0.05), and a weak but statistically significant correlation between intermediate VA and pupil size (r2=0.017; p< 0.05). No correlations were observed after 3 weeks for any distance (all p≥ 0.05). Participants rated subjective vision highly (84.0± 19.9, 89.2± 11.8, and 82.5± 18.5, respectively at 1 week, and 84.6± 18.0, 89.3± 12.6, and 84.2± 17.9, respectively at 3 weeks). Responses were favorable at both visits (p< 0.05). Correlations between vision rating and pupil size were not significant at either visit (p≥ 0.05).Conclusion: The kalifilcon A daily disposable silicone hydrogel MFCL delivers stable VA and significantly favorable (p< 0.05) ratings at all distances for patients with a wide range of pupil sizes.Keywords: presbyopia, visual acuity, progressive multifocal design, contact lens

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.011

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.183
GPT teacher head0.544
Teacher spread0.361 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueDOAJ (DOAJ: Directory of Open Access Journals)Same topicOcular Surface and Contact LensFrench-language works237,207