Abstract

fetched live from OpenAlex

Objectif : Déterminer la capacité de la séquence IRM 4D flow à mesurer la forme et le flot (débit, vélocité) de l’artère hépatique et de ses branches en trois dimensions. Méthodologie : Un fantôme de l’artère hépatique réaliste qui imite le flux sanguin et les mouvements respiratoires ainsi que 20 volontaires ont été imagés. La précision du 4D flow Cartésien avec navigateur et remplissage de l’espace-k selon la position respiratoire était déterminée in-vitro à quatre résolutions spatiales (0,5 à 1,0 mm isotropique) et fenêtres d’acceptation du navigateur (± 8 et ± 2 mm) avec un scanner IRM à 3T. Deux séquences centrées sur les branches hépatiques et gastroduodénales étaient évaluées in-vivo et comparés au contraste de phase 2D. Résultats : In vitro, l’augmentation de la résolution spatiale diminuait plus l’erreur qu’une fenêtre d’acceptation plus étroite (30.5 à -4.67% vs -6.64 à -4.67% pour le débit). In vivo, les artèreshépatiques et gastroduodénales étaient mieux visualisées avec la séquence de haute résolution (90 vs 71%). Malgré un accord interobservateur similaire (κ = 0.660 et 0.704), la séquence à plus haute résolution avait moins de variabilité pour l’aire, le débit, et la vélocité moyenne. Le 4D flow avait une meilleure cohérence interne entre l’afflux et l’efflux à la bifurcation de l’artère hépatique (1.03 ± 5.05% et 15.69 ± 6.14%) que le contraste de phase 2D (28.77 ± 21.01%). Conclusion : Le 4D flow à haute résolution peut évaluer l’anatomie et l’hémodynamie de l’artère hépatique avec une meilleure précision, visibilité, moindre variabilité et meilleure concordance interne.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.011

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.005
GPT teacher head0.196
Teacher spread0.191 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2023
Admission routes1
Has abstractyes

Explore more

Same venuePapyrus : Institutional Repository (Université de Montréal)Same topicOrgan Transplantation Techniques and OutcomesFrench-language works237,207