Application of supercapacitors to improve power quality in the electrical networks with distributed generation.
Bibliographic record
Abstract
The results of theexperimental investigations of supercapacitors as means for smoothing the voltage deviations and fluctuations are presented.PSCAD software (Canada) simulation models for equivalent circuits of the supercapacitor and experimental setup with photovoltaic panel are considered. Technique.To obtain the charge and discharge curves of supercapacitors, an experimental setup with photovoltaic panel was developed and tested under actual operatingconditions. It includes a 10 W photovoltaic panel, 100 Fsupercapacitors with 2.7 V rated voltage, voltage converters, and 4 W incandescent lamp with 12 V rated voltage used as a load. To measure and register voltages in different nodes of theexperimental setup, a Sanwa PC 510a digital multimeter altogether with PC Link software (Japan) were used. Besides the experimental investigations with Sanwa PC 510a digital multimeter and PC Link software, simulation by using of PSCAD software was executed in order to obtain the charge curve of supercapacitors. Results.An experimental setup to monitor and analyze the electromagnetictransientsin the electrical networks with photovoltaic panels is demonstrated. So-called "single-diode model" (equivalent circuit for photovoltaic panel) and equation describing a current-voltage characteristic of the practical photovoltaic module with several connected cells are given. Analytical expressions have been derived to obtain the parameters of the equivalent circuit for photovoltaic panel which are not typically available from manufacturer's data. Scientific novelty.Efficiency of supercapacitors as means for smoothing the voltage deviations and fluctuations arising from operation of photovoltaic panels was approved by means of experimental investigations. Practical value.The presented in paper experimental setup is used in training purposes of the State Higher Education Institution «Pryazovskyi State Technical University» during laboratory works on the subject«Alternative sources of electrical energy».
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.004 | 0.001 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.000 |
| Bibliometrics | 0.001 | 0.005 |
| Science and technology studies | 0.001 | 0.002 |
| Scholarly communication | 0.000 | 0.001 |
| Open science | 0.004 | 0.001 |
| Research integrity | 0.000 | 0.001 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".