MétaCan
Menu
Back to cohort
Record W7026770295

Anatomical and Functional Lung Imaging with Volumetric Computed Tomography in Non-Small Cell Lung Cancer

2022· article· en· W7026770295 on OpenAlexaboutno aff

Bibliographic record

VenueScholarship@Western (Western University) · 2022
Typearticle
Languageen
FieldMedicine
TopicEffects of Radiation Exposure
Canadian institutionsnot available
Fundersnot available
KeywordsImaging phantomLung cancerContouringRadiation therapyComputed tomographyScannerMedical imagingPositron emission tomography
DOInot available

Abstract

fetched live from OpenAlex

Non-small cell lung cancer (NSCLC) is one of the most diagnosed cancers in Canada, and the leading cause of cancer deaths. A significant challenge in treating NSCLC is balancing aggressive treatment with the potentially severe side effects. In radiation therapy, the management of respiratory motion and the risks of radiation-induced lung injury (RILI) pose significant challenges. 4-dimensional computed tomography (4D-CT) is an important part of motion management, but images often suffer from motion-induced artifacts. Volumetric CT scanners with wide axial field-of-view (aFOV) may reduce these artifacts and present an opportunity to advance CT-based functional lung imaging.\nChapter 2 presents a phantom imaging study to investigate the suitability of a 256-slice volumetric CT (vCT) scanner for radiotherapy treatment planning. The density of the highest density materials was under-estimated by the scanner, which can be addressed with the use of an appropriate relative electron density (RED) curve. An average RED curve for all aFOV settings may be used.\nChapter 3 presents a study of phantom and NSCLC patient 4D-CT images acquired on a clinical scanner and a vCT scanner. The v4D-CT images were re-sampled to simulate a conventional acquisition using a narrow aFOV clinical scanner. The phantom images demonstrated that target contouring variability decreased in v4D-CT imaging as compared to clinical 4D-CT. In the patient images, mean Hausdorff distance between organs at risk (OAR) contours was significantly correlated to respiratory phase, indicating that motion artifacts contribute to this variability.\nChapter 4 presents a novel acquisition and analysis pipeline to image lung ventilation (V), perfusion (Q) and V/Q ratio in a single volumetric CT scan. In a porcine study, these images of V and Q were significantly correlated to standard Xe-enhanced ventilation and PET perfusion images in voxel-wise analysis. In a NSCLC patient study, the images were sensitive to changes in V and Q between baseline imaging and follow-up 6 weeks after radiotherapy.\nIn this thesis, I demonstrate that volumetric CT scanners are suitable for use in radiation therapy simulation and treatment planning, and detail two scanning protocols which may reduce the challenges posed by respiratory motion and RILI risk in NSCLC.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.005
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0020.002
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.020
GPT teacher head0.264
Teacher spread0.244 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueScholarship@Western (Western University)Same topicEffects of Radiation ExposureFrench-language works237,207