MétaCan
Menu
Back to cohort
Record W7029186798

Investigation of the effects of humidity and surface charge on partial discharge in insulator posts under DC voltage

2020· dissertation· en· W7029186798 on OpenAlexaboutno aff

Bibliographic record

VenueMspace (University of Manitoba) · 2020
Typedissertation
Languageen
FieldMaterials Science
TopicHigh voltage insulation and dielectric phenomena
Canadian institutionsnot available
Fundersnot available
KeywordsInsulator (electricity)Arc flashPartial dischargeHumidityMoistureWindageVoltageHigh voltageSmoothingElectric field
DOInot available

Abstract

fetched live from OpenAlex

The flashover mechanism and performance of insulators have always been significant of importance to insulation engineers’ attention. A serious flashover accident will damage insulators and influence the reliability of the whole converter station and result in severe outages. It is believed that the flashover and partial discharge phenomena are strongly related to environmental conditions such as temperature, humidity, pressure, pollution's, and even space charges. The motivation of this thesis was to study the random discharge phenomenon that was observed in a Manitoba Hydro's HVDC substation to avoid further insulation damages. However, the lack of data prevents engineers from making firm conclusions. As such a data acquisition system was proposed that will collect leakage current data flowing in a reactor’s insulation post, to help to build a better understanding of the correlation between PD and environmental influences. The field tests at the HVDC substation studied the behavior of the leakage current from smoothing reactor’s ground wire and its associated electric field changes. Through the field tests, we found that the discharge phenomena exists only under certain weather conditions were. One hypothesis for partial discharge occurring on the insulator stacks is the influences of moisture and static charge. Moisture helps the static charge buildup on the insulator will spread along the insulator surface and create a conducting path between the smoothing reactor, flange, and ground. The sharp edge of the flange within this conducting path will generate corona and cause a discharge problem. For the laboratory experiments, humidity and surface charge studies were implemented in air and on FRP insulators under HVDC in order to get a better understanding of environmental influences on partial discharge behaviors. The results demonstrated that for a given electrode configuration, both humidity and surface charge have significant effects on the behavior of partial discharge. We also noticed that the relationship between total charge magnitude Q and equivalent frequency F followed a curve with exponential decay, and under high humidity environment or with surface charge present, the decay speed was faster than normal conditions. And the lab results also proved that time-frequency-charge (TFQ) mapping technique can be used for HVDC PD identifications.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.013
GPT teacher head0.201
Teacher spread0.188 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueMspace (University of Manitoba)Same topicHigh voltage insulation and dielectric phenomenaFrench-language works237,207