MétaCan
Menu
Back to cohort
Record W7033745225

Simulação numérica de um sistema de refrigeração com rejeição de calor para águas sanitárias a dois estágios, usando o fluido frigorigeneo CO2

2022· dissertation· pt· W7033745225 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

aboutThe title or abstract carries a Canadian signal from the geographic lexicon.
no affNo Canadian affiliation: this work is invisible to an affiliation-only frame.
No Canadian affiliation. An affiliation-only frame, the usual design, would never have seen this work. It is one of the works that make the case for inverting the frame.

Bibliographic record

VenueSapientia (Algarve University) · 2022
Typedissertation
Languagept
FieldEconomics, Econometrics and Finance
TopicDiverse Scientific and Economic Studies
Canadian institutionsnot available
Fundersnot available
KeywordsPower consumptionMaterials testingFlight test
DOInot available

Abstract

fetched live from OpenAlex

Devido ao aquecimento global e o peso energético que os sistemas de refrigeração têm em termos de consumo, os fluidos frigorigéneos ditos naturais têm vindo a ganhar relevo na indústria de refrigeração e ar condicionado e a eliminar gradativamente os fluidos frigorigéneos convencionais (HCFCs e HFCs), de acordo com as regularizações definidas pelo protocolo de Montreal-Emenda de Kigali. A presente dissertação de mestrado pretende dimensionar um sistema de refrigeração para um matador fictício de frangos. Trata-se de uma instalação frigorífica para apoiar uma linha de abate de frangos de um matadouro situado nas ilhas Seychelles. O sistema proposto pela presente dissertação é definido por um sistema de refrigeração a dois estágios com recuperação de calor para lavagem industrial, usando o fluido frigorigéneo CO₂. Nesta dissertação são efetuadas duas simulações numéricas por meio do software EES (Engineering Equation Solver) do sistema de refrigeração, isto é um estudo comparativo entre uma simulação do EES onde a potência frigorifica do estágio de baixa temperatura e do estágio de média temperatura são considerados variáveis independentes e a outra simulação em que as potências frigorificas (baixa e média) são variáveis dependentes e são aplicadas equações polinominais fornecidos por um fabricante (Bitzer) para o cálculo das potências do compressores, consumo elétrico do compressores e os caudais mássicos dos compressores. Também são comparados os resultados efetuados com a simulação numérica a partir do EES e do software da Bitzer. Igualmente, são descritos alguns componentes do sistema de refrigeração, nomeadamente: -Arrefecedor de Gás -Recuperador de Calor -Compressor -Evaporador -Permutador de Calor Interno -Válvulas de Expansão -Válvula de alta temperatura -Válvula de By-pass Para finalizar, efetuou-se uma análise financeira para demonstrar a viabilidade económica em usar a recuperação de calor do sistema de refrigeração para o aquecimento das águas para lavagem industrial, em vez de uma caldeira a gás natural.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Science and technology studies, Insufficient payload (model declined to judge)
Consensus categoriesInsufficient payload (model declined to judge)
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: Not applicable
GenreCandidate signal: Other · Consensus signal: none
Teacher disagreement score0.472
Threshold uncertainty score0.999

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.000
Meta-epidemiology (narrow)0.0010.002
Meta-epidemiology (broad)0.0020.001
Bibliometrics0.0020.002
Science and technology studies0.0030.000
Scholarly communication0.0010.001
Open science0.0020.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0260.005

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.029
GPT teacher head0.229
Teacher spread0.200 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it