Heat Exchangers for Waste Heat Recovery
Bibliographic record
Abstract
To reduce energy consumption and water heating requirements, the Ontario Building Code mandates every new residential building must install a drain water heat recovery unit to recover energy from drain water. A two-stage waste heat recovery unit is designed and tested with conformance to the Ontario Building Code. A novel leak detection system was implemented by measuring the electrical resistance of a coating. Thermal spray coating processes are used to create surfaces with enhanced performance. Flame spray and wire-arc spray produced two and three samples respectively. Each sample is tested to find the best heat transfer occurred with 0.125” diameter pillars, staggered, spaced 0.188” with enhanced surface area of 45.8% while increasing the convective heat transfer coefficient by 26.1% - 64.4% depending on the Reynolds number between 281 and 2745. The coatings are recommended to be utilized in a flat plate design with reduced complexity, size, and cost.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.000 |
| Meta-epidemiology (narrow) | 0.001 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.001 |
| Bibliometrics | 0.001 | 0.001 |
| Science and technology studies | 0.001 | 0.000 |
| Scholarly communication | 0.001 | 0.001 |
| Open science | 0.001 | 0.001 |
| Research integrity | 0.001 | 0.001 |
| Insufficient payload (model declined to judge) | 0.022 | 0.009 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".