MétaCan
Menu
Back to cohort
Record W7043833326

Succinylcholine Use and Dantrolene Availability for Malignant Hyperthermia Treatment: Database Analyses and Systematic Review

2019· article· en· W7043833326 on OpenAlexaboutno aff

Bibliographic record

VenueUtrecht University Repository (Utrecht University) · 2019
Typearticle
Languageen
FieldBiochemistry, Genetics and Molecular Biology
TopicIon channel regulation and function
Canadian institutionsnot available
Fundersnot available
KeywordsDantroleneMalignant hyperthermiaAmbulatoryAirwayPerioperativeMuscle relaxantSugammadexMEDLINEProtocol (science)
DOInot available

Abstract

fetched live from OpenAlex

Editor's Perspective What We Already Know about This Topic Dantrolene effectively treats malignant hyperthermia, but there are discrepant recommendations for dantrolene availability in facilities that stock succinylcholine for airway rescue but do not use volatile anesthetics. What This Article Tells Us That Is New The authors performed an analysis of data from three databases and a systematic literature review. Providers frequently use succinylcholine, including during difficult mask ventilation. Succinylcholine given without volatile anesthetics triggered 24 malignant hyperthermia events, 13 of which were treated with dantrolene. Fourteen patients experienced substantial complications, and one died. Delayed dantrolene treatment worsened patient outcomes. Background: Although dantrolene effectively treats malignant hyperthermia (MH), discrepant recommendations exist concerning dantrolene availability. Whereas Malignant Hyperthermia Association of the United States guidelines state dantrolene must be available within 10 min of the decision to treat MH wherever volatile anesthetics or succinylcholine are administered, a Society for Ambulatory Anesthesia protocol permits Class B ambulatory facilities to stock succinylcholine for airway rescue without dantrolene. The authors investigated (1) succinylcholine use rates, including for airway rescue, in anesthetizing/sedating locations; (2) whether succinylcholine without volatile anesthetics triggers MH warranting dantrolene; and (3) the relationship between dantrolene administration and MH morbidity/mortality. Methods: The authors performed focused analyses of the Multicenter Perioperative Outcomes Group (2005 through 2016), North American MH Registry (2013 through 2016), and Anesthesia Closed Claims Project (1970 through 2014) databases, as well as a systematic literature review (1987 through 2017). The authors used difficult mask ventilation (grades III and IV) as a surrogate for airway rescue. MH experts judged dantrolene treatment. For MH morbidity/mortality analyses, the authors included U.S. and Canadian cases that were fulminant or scored 20 or higher on the clinical grading scale and in which volatile anesthetics or succinylcholine were given. Results: Among 6,368,356 queried outcomes cases, 246,904 (3.9%) received succinylcholine without volatile agents. Succinylcholine was used in 46% (n = 710) of grade IV mask ventilation cases (median dose, 100 mg, 1.2 mg/kg). Succinylcholine without volatile anesthetics triggered 24 MH cases, 13 requiring dantrolene. Among 310 anesthetic-triggered MH cases, morbidity was 20 to 37%. Treatment delay increased complications every 10 min, reaching 100% with a 50-min delay. Overall mortality was 1 to 10%; 15 U.S. patients died, including 4 after anesthetics in freestanding facilities. Conclusions: Providers use succinylcholine commonly, including during difficult mask ventilation. Succinylcholine administered without volatile anesthetics may trigger MH events requiring dantrolene. Delayed dantrolene treatment increases the likelihood of MH complications. The data reported herein support stocking dantrolene wherever succinylcholine or volatile anesthetics may be used.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.571
Threshold uncertainty score0.837

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.025
GPT teacher head0.233
Teacher spread0.208 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueUtrecht University Repository (Utrecht University)Same topicIon channel regulation and functionFrench-language works237,207