MétaCan
Menu
← Back to cohort
Record W7045913044

Characterization of pyrene films for background rejection in liquid argon dark matter experiments

2021· dissertation· en· W7045913044 on OpenAlexfundno aff

Bibliographic record

VenueQSpace (Queen's University Library) · 2021
Typedissertation
Languageen
FieldPhysics and Astronomy
TopicMagnetic confinement fusion research
Canadian institutionsnot available
FundersQueen's University
KeywordsPyreneAnalytical Chemistry (journal)Dark matterWIMPArgonRecoilFluorescenceYield (engineering)
DOInot available

Abstract

fetched live from OpenAlex

About a hundred years after the first references to dark matter, the mystery around the nature of that elusive type of matter has still not been solved. Direct detection dark matter experiments are getting more and more sensitive but still face a lot of various backgrounds. We focus here on DEAP-3600, a liquid argon (LAr) target WIMP detector for which pulse shape discrimination (PSD) techniques are particularly efficient to distinguish nuclear recoils (NR), events characteristic of WIMP-argon interaction, from electronic recoil (ER) background events. However, α-events occurring in the neck of the DEAP-3600 detector lead to shadowed nuclear recoil-like events which mimic WIMP low energy scintillation pulse shape. Applying a wavelength shifter coating with high light yield and slow decay in the neck of the detector is expected to lead to a discrimination power of O(10^5) assuming a 100% signal acceptance. This thesis investigates the fluorescence properties of the favoured coating candidate, a pyrene-polystyrene thin film that could alter the pulse shape of these α-events in order to take them out of the WIMP region of interest. Emission spectra, fluorescence yield and fluorescence time constants were studied at 18 temperatures between 4 K and 300 K, including room temperature and LAr temperature (87 K), for several pyrene-polystyrene samples with varied pyrene concentrations (12% and 15%) and purities (98%, 99% and 99.9%). The highest pyrene concentration (15% pyrene) and the highest pyrene purity (99.9%) were found to have the highest light yield at all temperatures. At LAr temperature, the light yield of the 99.9% purity 15% pyrene sample relative to 1,1,4,4-tetraphenyl- 1,3-butadiene (TPB), a wavelength shifter commonly used in dark matter detectors, was found to be 45%. The highest pyrene purity samples (99.9% purity) also showed the slowest decay. The fluorescence profiles were modelled first using an adhoc model with a bi-exponential decay. The majority of the light at LAr temperature for both 12% and 15% concentration samples (99.9% purity) was found to be dominated by a decay with time constant higher than 250 ns. Overall, the 15% pyrene (99.9% purity) sample showed the highest potential for discrimination of DEAP-3600 neck α-events. For this sample, pyrene monomer and excimer fluorescence profiles were separated and modelled separately. At LAr temperature, the decay was dominated by the monomer fluorescence profile, a 293 ± 7 ns decay.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.227
Teacher spread0.218 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueQSpace (Queen's University Library)→Same topicMagnetic confinement fusion research→French-language works237,207→