MétaCan
Menu
Back to cohort
Record W7054872212

A Buccal Mucosal Oximeter Accurately Measures Arterial Oxyhemoglobin Saturation

2025· article· en· W7054872212 on OpenAlexaboutno aff

Bibliographic record

VenueDOAJ (DOAJ: Directory of Open Access Journals) · 2025
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Frequency and Time Standards
Canadian institutionsnot available
Fundersnot available
KeywordsBuccal administrationUniversity hospitalMedical schoolSleep apnea syndromesHuman physiologyBuccal mucosa
DOInot available

Abstract

fetched live from OpenAlex

Connor Snow,1– 3 Shane Magnison-Benoit,1– 3 Matiram Pun,1– 3 Thomas R Tripp,1– 3 Aimee Clarke,1– 3 Sophie Berghmans,1– 3 Bradley Hansen,1– 3 Leo Transfiguracion,4 Saleema Adatia,5 Jean M Rawling,6 Steven Roy,7,8 Giovanni Di Simone,9 Ming-Lai Lai,9 Erin V Mosca,9 John E Remmers,9 Marc J Poulin1– 3,8,10,11 1Department of Physiology and Pharmacology, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada; 2Hotchkiss Brain Institute, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada; 3Faculty of Kinesiology, University of Calgary, Calgary, Alberta, Canada; 4Department of Anesthesia, Alberta Health Services, Calgary, Alberta, Canada; 5Symmetry Dental, Calgary, Alberta, Canada; 6Department of Family Medicine, University of Calgary, Calgary, Alberta, Canada; 7Department of Critical Care Medicine, University of Calgary, Calgary, Alberta, Canada; 8O’Brien Institute for Public Health, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada; 9ProSomnus Sleep Technologies, Pleasanton, CA, USA; 10Libin Cardiovascular Institute of Alberta, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada; 11Department of Clinical Neurosciences, Faculty of Medicine, University of Calgary, Calgary, Alberta, CanadaCorrespondence: Marc J Poulin, HMRB-210, 3330 Hospital Drive NW Cumming School of Medicine, University of Calgary, Calgary, Alberta, T2N 4N1, Canada, Tel +1 403-220-8372, Email poulin@ucalgary.caPurpose: While arterial oxyhemoglobin saturation (SaO2) decreases during sleep in many patients with sleep apnea and pulmonary diseases, personalized oximeters suitable for multi-night monitoring of SpO2 are not readily available. The present report describes a custom buccal mucosal intraoral oximeter that might provide the opportunity for such long-term monitoring given its strong accuracy in measuring SpO2 over a range of clinically relevant hypoxemia.Patients and Methods: The intraoral buccal mucosal oximeter was constructed by encapsulating a reflectance pulse oximeter in an overlay of the maxillary dentition. Accuracy was assessed during non-motion conditions in normal participants (n = 12) made progressively hypoxic by decreasing the partial pressure of end-tidal oxygen (PETO2). CO-oximeter values of SaO2 from arterial blood constituted the “gold standard” for comparison with the buccal mucosal oximeter’s values. The oximeter’s pulse rate and an electrocardiogram (ECG) determined heart rate were also compared.Results: Analysis of 325 paired SaO2 values from the CO-oximeter and buccal mucosal oximeter yielded the following: r = 0.95; bias = 0.72; and accuracy root-mean-square (ARMS) = 2.94%. Results from the pulse rate/ECG analysis were: r = 0.99; bias = 0.30; and ARMS = 2.08 bpm.Conclusion: These results reveal robust accuracy of the buccal mucosal oximeter measurement of SaO2 and pulse rate, as shown by good agreement with a “gold standard” over a wide range of arterial hypoxemia. Such clinically acceptable accuracy indicates that this novel reflectance oximeter may prove useful in management of patients with sleep-induced hypoxemia by allowing for long-term monitoring of SaO2.Keywords: hypoxia, oximetry, intraoral pulse oximeter, respiratory monitoring, obstructive sleep apnea, remote patient monitoring

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Scholarly communication, Insufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.331
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0010.002
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0130.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.185
GPT teacher head0.546
Teacher spread0.361 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueDOAJ (DOAJ: Directory of Open Access Journals)Same topicAdvanced Frequency and Time StandardsFrench-language works237,207