Prediction and Control of Transient Instability Using Wide Area Phasor Measurements

2011· dissertation· en· W7061067408 on OpenAlexaboutno aff

Bibliographic record

VenueMspace (University of Manitoba) · 2011
Typedissertation
Languageen
FieldEngineering
TopicTerahertz technology and applications
Canadian institutionsnot available
Fundersnot available
KeywordsControl theory (sociology)PhasorElectric power systemTransient (computer programming)VoltageTransient voltage suppressorFuzzy logicFuzzy control system
DOInot available

Abstract

fetched live from OpenAlex

This thesis presents a novel technique for prediction of the transient stability status of a power system following a large disturbance such as a fault, and application of the tech-nique for subsequent emergency control. The prediction is made based on the synchro-nously measured samples of the magnitudes of fundamental frequency voltage phasors at major generation/load centers. The voltage samples are taken immediately after a fault is cleared and used as inputs to a binary classifier based on support vector machines to iden-tify the transient stability condition. The classifier is trained using examples of the post-fault recovery voltages (inputs) obtained through simulations and the corresponding sta-bility status (output) determined using a power angle-based stability index. Studies with the New England 39-bus test system indicate that the proposed algorithm can correctly recognize when the power system is approaching transient instability. The proposed sys-tem is then applied to Venezuelan power system and Manitoba Hydro power grid to demonstrate the applicability for large practical power systems. Performance of the pro-posed transient stability prediction scheme under the presence of asymmetrical faults, voltage sensitive loads, unlearned network topologies and measurement noise was found to be satisfactory. Once an impending transient instability situation has been detected, appropriate emer-gency control strategies are triggered to minimize the impact of this on the safe operation of the network and reduce the possibility of a blackout. This thesis examines two differ-ent emergency control schemes: a) A fuzzy logic based emergency load and generator shedding scheme and b) A high voltage direct current (HVdc) power order reduction scheme based on synchronized phasors measurements. These strategies were developed for two power systems with contrasting characteristics: one for the Venezuelan power system which is a conventional power system completely based on alternating current (AC) transmission, and the other for the Manitoba Hydro network which heavily depend on long HVdc transmission for power transfer. The proposed wide area control systems demonstrated good performance on the Venezuelan and Manitoba Hydro power grids.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.002
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.031
GPT teacher head0.191
Teacher spread0.160 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2011
Admission routes1
Has abstractyes

Explore more

Same venueMspace (University of Manitoba)Same topicTerahertz technology and applicationsFrench-language works237,207