MétaCan
Menu
Back to cohort
Record W7061303342

Perancangan Sistem Plambing Perpustakaan Daerah Kuantan Singingi

2023· dissertation· en· W7061303342 on OpenAlexaff

Bibliographic record

VenueAndalas University eThesis (Andalas University) · 2023
Typedissertation
Languageen
FieldPhysics and Astronomy
TopicGyrotron and Vacuum Electronics Research
Canadian institutionsEncana (Canada)
Fundersnot available
KeywordsPipingSewerageWater circulationMains electricityHazard
DOInot available

Abstract

fetched live from OpenAlex

The Kuantan Singingi Regency and Riau Province governments erected the Kuantan Singingi Regional Library to improve the quality of community literacy. This library is located in Jalan H Abdoer Rauf and has 4 floors. The plumbing systems design for the building includes water supply systems, sewerage distribution systems, vent systems, rainwater distribution systems, and fire hazard prevention systems. The design of plumbing systems based on SNI 8153:2015 concerning Plumbing Systems in Buildings as well as other standards and regulations related. The water supply system uses a roof tank system with a water source from a deep drilled well. The tanks used 3 FRP tanks and 2 compartment bottom tanks. A booster pump with Np = 0.43 kW and Nm = 0.51 kW is needed in the distribution piping. The sewerage distribution system divided into dirty water distribution system and used water distribution system which designed separately. Wastewater channeled into 2 bio septic tanks with a capacity of 30 m3. Vent systems used are individual vents, circuit vents, shared vents, loop vents, and branch vents. The rainwater distribution system had a different piping system from wastewater. Rainwater is channeled through horizontal pipes and vertical pipes to the infiltration field with a channel length of 3 m. The library classified as a building with moderate fire hazard group II. The fire prevention system used hydrant system, 1 unit per floor, and a sprinkler system. The drinking water supply system used PVC pipes with a diameter of 32 mm – 75 mm. The dirty water and used water distribution system uses PVC pipes with diameters of 63 mm – 110 mm and 32 mm – 50 mm respectively. The rainwater distribution system used PVC supralon pipes with diameters of 50 mm and 75 mm. The fire prevention system uses 25 mm – 100 mm GIP pipes. The total costs required for the plumbing system work project in the Kuantan Singingi Regional Library building are Rp.2,800,000,000.00-, (Two Billion Eight Hundred Million Rupiah).

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Science and technology studies
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.848
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0020.002
Science and technology studies0.0020.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.231
Teacher spread0.219 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designNot applicable
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueAndalas University eThesis (Andalas University)Same topicGyrotron and Vacuum Electronics ResearchFrench-language works237,207