MétaCan
Menu
Back to cohort
Record W7070768613

Radiation protection of aircraft crew: publicly available database of measurements with the silicon spectrometer Liulin on board aircraft

2014· other· en· W7070768613 on OpenAlexaboutno aff

Bibliographic record

VenueQST-Repository (National Institutes for Quantum and Radiological Science and Technology) · 2014
Typeother
Languageen
Field
Topic
Canadian institutionsnot available
Fundersnot available
KeywordsAircrewDosimeterAirplaneRadiation protectionSpectrometerOak Ridge National LaboratoryCriticalityRadiation
DOInot available

Abstract

fetched live from OpenAlex

Annual effective doses of aircrew from occupational exposure are typically up to 6 mSv, depending on the number of flight hours, route locations, and solar activity. In many cases, these doses exceed the limit for public exposure to ionizing radiation and thus ICRP recommended their monitoring. Radiation fields at aircraftaltitudes are complex and difficult to measure experimentally. For this reason, the doses are estimated via computer codes that take into account flight parameters like aircraft location and altitude, and solar activity. It is generally accepted, that these calculations should be periodically verified by measurements. Precisemeasurements with tissue equivalent proportional counters are typically short-term only as these detectors are bulky and have only limited battery life. For long-term measurements, which are needed to cover the whole 11-year solar cycle, the silicon spectrometer Liulin is better suited. Liulin is an active dosimeter which records energy deposition events occurring in the semiconductor unit, and – if appropriately calibrated – it estimates neutron and non-neutron component of the ambient dose equivalent. This paper presents a database of long-term measurements performed on board aircraft with the Liulin detector. The measurements started in 2001. For one run, Liulin was placed in the cabin of a Czech Airlines aircraft for approximately 50 days. So far 28 runs were performed, i. e. about 3 500 flights and almost 20 000 flight hours. Flights were flown from Prague to destinations with vertical cut-off rigidities ranging from 1 GV to 17 GV. The most frequent were transatlantic flights from Prague to New York and to Canada. The database comprises more than 105 records where each record contains information on: energy deposition spectra, absorbed dose rates and dose equivalent rates measured with Liulin, date and time, geographic coordinates and altitude. The data are available on the Internet and can be used for instance for verification of computational programs routinely used for estimation of aircrew exposure to cosmic radiation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesScience and technology studies
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.517
Threshold uncertainty score0.998

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0010.005
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.034
GPT teacher head0.256
Teacher spread0.221 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2014
Admission routes1
Has abstractyes

Explore more

Same venueQST-Repository (National Institutes for Quantum and Radiological Science and Technology)French-language works237,207