Bibliographic record
Abstract
Passive cooling by means of pressured heat exchange pipes was developed in Alaska by the U.S. Army Corps of Engineers in 1965 to preserve foundations in ‘warm ’ permafrost. It has been widely applied in Alaska, northern Canada and Russia to preserve and cool permafrost. The original simple 20mm vertical pipe with a radiator in the air has evolved into other designs that include: thermopiles, sloped pipe thermosyphons and flat loop evaporator pipe (flat loop) thermosyphons. The flat loop thermosyphon was developed and field tested in Canada in 1994 to allow the construction of buildings directly on the ground, slab-on-grade. Subsequently this design started to be used also for buildings with crawl space. The thermosyphon is a closed natural two phase convection device that extracts heat from the ground and discharges it into the atmosphere. The gas/fluid medium is carbon dioxide that functions in a closed ‘pipe’, pressure vessel, under a pressure varying from about 300 to 700 psi. The thermosyphon draws out the heat from below the building by a heat exchange mechanism. During the winter the outside air is colder than the ground temperature causing the gas in the pipe above the ground to condense and flow to the base of the pipe. The cold
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.001 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".