MétaCan
Menu
← Back to cohort
Record W7106005687 · doi:10.4224/7tdd-jh78

Quebec Construction Code, Chapter I: Building, and National Building Code of Canada 2020 (amended)

2025· standard· en· W7106005687 on OpenAlexvenueaboutno aff

Bibliographic record

VenueNPARC · 2025
Typestandard
Languageen
Field
Topic
Canadian institutionsnot available
Fundersnot available
KeywordsBuilding codeServiceability (structure)SignagePedestrianDemolitionFire protectionDivision (mathematics)

Abstract

fetched live from OpenAlex

This document, published by the National Research Council of Canada for the Régie du bâtiment du Québec, contains both the new edition of Chapter I, Building, of the Quebec Construction Code, and an amended version of the National Building Code of Canada 2020 that clearly indicates the changes adopted by Quebec. This document is a useful resource for designers, contractors and owner-builders in particular. This document sets out technical requirements applicable to the construction of buildings and facilities intended for use by the public in Quebec. Key changes in the new edition include the following modifications: • The introduction of a new type of construction, encapsulated mass timber construction, for timber buildings up to 12 storeys • The improvement of building accessibility through: o a revision of the minimum dimensions of building components o the introduction of requirements for universal bathrooms and showers, visible and audible signals, and tactile safety signage o an increased number of accessible pedestrian entrances and floors • The introduction of home-type care occupancies (Group B, Division 4), a new major occupancy subject to the requirements in Part 9 of Division B • New technical requirements for large farm buildings, which are introduced in the new Part 2 of Division B • Changes to Parts 3 and 9 of Division B, which include the following topics: o penetrations and continuity of fire separations o safety glazing • The introduction of changes relating to structural design in Part 4 of Division B, include the following topics: o classification of buildings o serviceability limit states o design of roof parking decks o design of floor slabs o snow drifting o design of roof-mounted solar panels o design of parapets o design of attached canopies o design of storage garages o updated wind design data • The introduction of changes to Part 5 of Division B, including for the following topics: o airtightness o new material standards • The introduction of changes to Part 6 of Division B, including new requirements for evaporative heat rejection systems to minimize the risk of the presence of disease-causing micro-organisms such as Legionella • The introduction of changes to Part 9 for the protection from soil gas ingress

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.009
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: Not applicable
GenreCandidate signal: Other · Consensus signal: Other
Teacher disagreement score0.143
Threshold uncertainty score0.511

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.009
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0030.006
Science and technology studies0.0050.001
Scholarly communication0.0060.002
Open science0.0030.001
Research integrity0.0030.003
Insufficient payload (model declined to judge)0.1430.067

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.260
Teacher spread0.249 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreOther

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2025
Admission routes2
Has abstractyes

Explore more

Same venueNPARC→French-language works237,207→