MétaCan
Menu
Back to cohort
Record W7116986226 · doi:10.1186/s13054-025-05810-z

Monitoring diaphragmatic effort during diaphragm neurostimulation-assisted ventilation

2025· article· en· W7116986226 on OpenAlexafffund
Andrea Castellvi-Font, Idunn S. Morris, Francisco José Parrilla-Gómez, Matías Madormo, Catherine A. Bellissimo, Viral Thakkar, N. Mehta, Thiago Bassi, Laurent J. Brochard, Niall D. Ferguson, E C. Goligher

Bibliographic record

VenueCritical Care · 2025
Typearticle
Languageen
FieldMedicine
TopicRespiratory Support and Mechanisms
Canadian institutionsToronto East General HospitalUniversity Health NetworkUniversity of TorontoToronto General HospitalSt. Michael's HospitalLungpacer Medical (Canada)
FundersNational Sanitarium Association
KeywordsDiaphragm (acoustics)Diaphragmatic breathingVentilation (architecture)Mechanical ventilationSpontaneous breathing trialNeurostimulationArtificial ventilationPressure support ventilation

Abstract

fetched live from OpenAlex

RATIONALE: Diaphragm neurostimulation-assisted ventilation (DNAV) can improve cardiopulmonary function during passive mechanical ventilation. However, this technique requires a reliable method to monitor and titrate diaphragmatic loading to avoid both insufficient and excessive diaphragmatic stimulation. OBJECTIVE: To establish whether the reduction in airway pressure-time product (ΔPTPaw) obtained during diaphragm neurostimulation in assist control volume-controlled mode accurately quantifies the magnitude of respiratory muscle effort elicited by neurostimulation. METHODS: This was a secondary analysis of the STIMULUS trial. Diaphragm neurostimulation was titrated across four levels targeting progressive occlusion pressures of 0, - 5, - 10, and - 15 cm H₂O at two PEEP levels. At each level, airway, esophageal, and gastric pressures were recorded to compute transdiaphragmatic pressure-time product (PTPdi), respiratory muscles pressure-time product (PTPmus), and ΔPTPaw, defined as the difference in airway pressure-time product between non-stimulated and stimulated breaths. Linear mixed-effects models, Bland-Altman analyses, and receiver operating characteristic (ROC) curves were used to assess agreement and discriminative ability. MEASUREMENTS AND MAIN RESULTS: Twelve patients contributed 494 high-quality respiratory cycles (63% of recorded cycles). Valid Pdi data were available in nine patients. Increasing neurostimulation was associated with higher PTPdi and PTPmus and a corresponding reduction in PTPaw. ΔPTPaw was correlated with both PTPdi (R² = 0.82) and PTPmus (R² = 0.92), with good agreement observed (limits: - 4 to 44 cm H₂O·s/min for PTPdi, and - 5 to 39 cm H₂O·s/min for PTPmus). ΔPTPaw demonstrated excellent discrimination for inadequate (area under receiver operating characteristic curve, AUROC ≥ 0.94) and excessive (AUROC ≥ 0.86) diaphragmatic effort. CONCLUSIONS: ΔPTPaw is a reliable, non-invasive surrogate for monitoring diaphragm loading during DNAV under assist-controlled volume-controlled mode and may guide neurostimulation titration in mechanically ventilated patients.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.004
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.022
GPT teacher head0.351
Teacher spread0.328 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2025
Admission routes2
Has abstractyes

Explore more

Same venueCritical CareSame topicRespiratory Support and MechanismsFrench-language works237,207