MétaCan
Menu
Back to cohort
Record W7117566863 · doi:10.1016/j.biosx.2025.100734

Recent advances in smart contact lenses

2025· article· en· W7117566863 on OpenAlexaff
Zahra Adibag, Mahsa Ghanbarzadeh, Mohammad Amin Salati, Monireh Esmaeili Rad, Rais Ansari, Christopher N. Ta, Daddi Fadel, Mohammad Mofidfar, Farhang Abbasi

Bibliographic record

VenueBiosensors and Bioelectronics X · 2025
Typearticle
Languageen
FieldMedicine
TopicOcular Surface and Contact Lens
Canadian institutionsUniversity of Waterloo
FundersNational Eye InstituteResearch to Prevent Blindness
KeywordsContact lensDrug deliveryBench to bedsideInstrumentation (computer programming)Remote patient monitoringFood and drug administrationIntraocular pressure

Abstract

fetched live from OpenAlex

The growing demand for healthcare services and recent advances in materials and biosensing technologies have accelerated the development of point-of-care (POC) diagnostics, with smart contact lenses (SmCLs) emerging as a promising platform. This review systematically evaluates the role of tear fluid as a noninvasive diagnostic medium, highlighting its biochemical composition and challenges in sample collection. We examine the design parameters essential for functional SmCLs, including biocompatibility, oxygen permeability, wettability, and mechanical properties, which collectively determine long-term comfort and device performance. SmCLs can significantly improve the bioavailability of drug delivery while addressing the limitations of traditional ocular treatments, such as the rapid dissipation of eye medications through the nasolacrimal duct. Furthermore, the potential of SmCLs in disease diagnosis through chemical and physical biomarker detection is highlighted, showcasing their ability to monitor glucose levels and intraocular pressure in real-time. Overall, current evidence supports SmCLs as multifunctional devices capable of combining diagnostics and therapy in real time. However, large-scale validation studies are required to establish clinical accuracy, patient adherence, and cost-effectiveness. This review concludes that SmCLs represents an innovative direction in personalized healthcare, integrating materials science, biosensing, and drug delivery for noninvasive, continuous health monitoring of ocular and system diseases. • Tear fluid enables noninvasive, real-time diagnostics using smart contact lenses. • SmCLs offer enhanced drug delivery, addressing limitations of eye drop treatments. • Advances in materials improve biocompatibility, comfort, and long-term wearability. • Integrated sensors in SmCLs can monitor glucose levels and intraocular pressure. • Clinical translation requires validation of accuracy, efficacy, and cost-effectiveness.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.915
Threshold uncertainty score0.402

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.008
GPT teacher head0.267
Teacher spread0.259 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueBiosensors and Bioelectronics XSame topicOcular Surface and Contact LensFrench-language works237,207