MétaCan
Menu
Back to cohort
Record W7120460475

Synchronous Generator Reactive Power Service: Technical and Regulatory Aspects

2008· dissertation· pt· W7120460475 on OpenAlexaboutno aff
Heraldo Silveira Barbuy

Bibliographic record

VenueLA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) · 2008
Typedissertation
Languagept
FieldEngineering
TopicPower System Optimization and Stability
Canadian institutionsnot available
Fundersnot available
KeywordsAC powerBiddingElectric power systemRemunerationGenerator (circuit theory)Work (physics)VoltageElectric powerVoltage optimisation
DOInot available

Abstract

fetched live from OpenAlex

This work analyzes the technical and regulatory aspects of reactive power supply ancillary services of synchronous generators and emphasizes that Brazilian rules do not stimulate investment for such purpose and this can degrade those resources. In the past, the electrical worldwide systems used to have a centralized public utility which could include the several costs of ancillary services for electric power supply in the final price of the active power. After the privatization and decentralization, there was the need to separate the remuneration for such ancillary services. The resolutions that rule the reactive power ancillary services of synchronous generators have developed differently in several world regions. In this work it is given a description of some foreign legislations, which are then compared to the present status of Brazilian legislation, indicating its questionable aspects. Indexes are proposed for the selection of generators to supply reactive power to some electric power system area. It is proposed the public bidding for this supply taking the indexes into account, so that the price will depend on the effective contribution of each generator to the voltage rise in the target area. Simulations are presented to illustrate that the generator choice depends upon its localization. The need of reactive power support to improve the security margin against voltage collapse can be indicated by several indexes. It is shown a top view of the voltage collapse proximity indicators, with emphasis to those selected for this work. Often the electric power system operators call for a reactive power redispatch for voltage profile correction, but it is shown that sometimes this procedure leads to a risk of voltage collapse The dynamical behavior of synchronous generator excitation systems is very important for the reactive power dispatch. The operator requirements from Brazil, USA and Canada are presented. It is proposed a technique for voltage regulator adjustment, taking into account the time constant, the regulation error and the ceiling voltage, with illustration by means of simulations. Concluding, several suggestions are synthesized towards the evolution of the legislation concerning to reactive power supply from synchronous generators.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Research integrity
Consensus categoriesMeta-epidemiology (narrow)
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.937
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0010.000
Scholarly communication0.0000.001
Open science0.0010.000
Research integrity0.0020.002
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.013
GPT teacher head0.230
Teacher spread0.218 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; both teacher heads agree on what is shown here.

Study designNot applicable
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2008
Admission routes1
Has abstractyes

Explore more

Same venueLA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas)Same topicPower System Optimization and StabilityFrench-language works237,207