Dynamic Analysis of a Pacemaker Lead Wire for Piezoelectric Energy Harvesting Applications
Bibliographic record
Abstract
Piezoelectric energy harvesters (PEH) for cardiac pacemakers typically use animal models to assess the performance of the PEH. However, if considering multiple designs, the use of animal models and prototyping increases costs and time. This study investigates the motion of a pacemaker lead wire in vivo to quantify the position and displacements as a function of time. Patient specific fluoroscopy imaging data was used, and image processing allowed for wire motion to be captured as discretized nodes. Simulations with an energy harvesting circuit using the nodal position and displacement data shows that a PEH integrated in the pacemaker lead wire can generate a direct current voltage of 1.12 V and power output of 0.125 μW, potentially extending the battery life of pacemakers by 1-1.25 years. The results show that fluoroscopy imaging data can be effective in evaluating designs before use in animal models, saving time and costs.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".