MétaCan
Menu
Back to cohort
Record W7134225551 · doi:10.1049/pbce137e_ch11

Calibration platform for wearable 3D motion sensors

2025· book-chapter· en· W7134225551 on OpenAlexaff
Bingfei Fan, Q. Li, Tao Liu

Bibliographic record

Venuenot available
Typebook-chapter
Languageen
FieldEngineering
TopicProsthetics and Rehabilitation Robotics
Canadian institutionsQueen's University
Fundersnot available
KeywordsGimbalCalibrationRotation (mathematics)Orientation (vector space)Wearable computerPosition (finance)Position sensorAccelerometerServomotor

Abstract

fetched live from OpenAlex

With the development of micro-electro-mechanical system (MEMS) technologies, wearable motion sensors (WMSs) have played an increasingly significant role in the design of exoskeletons, where the WMSs are used for motion detection, orientation estimation or position estimation. For these applications, the accuracy of the WMSs will affect the overall performance of the exoskeletons. The purpose of this chapter is to present an calibration platform for assessing the accuracy of WMSs, assisting in developing or choosing proper WMSs for exoskeletons. The presented calibration platform is an instrumented gimbal with three rotation axes. Each axis is equipped with a DC motor and an absolute encoder. Thus, each axis can be controlled independently, and the rotation angle around each axis can be output accurately. In addition, each axis can rotate continuously via the equipped electrical slip rings. One of the major advantages of the instrumented gimbal is that it can be used for accurate motion analysis without needing any additional equipment. In order to verify the function of the platform, validation experiments were conducted, including a static accuracy test and a dynamic accuracy test with and without magnetic disturbances. Results show that the designed gimbal has good potential for evaluating the orientation of WMSs under different conditions.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.022
Threshold uncertainty score0.074

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0220.011

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.209
Teacher spread0.197 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2025
Admission routes1
Has abstractyes

Explore more

Same topicProsthetics and Rehabilitation RoboticsFrench-language works237,207