MétaCan
Menu
← Back to cohort

Delivery of dornase alfa via breath-actuated nebulizer: In-vitro measures of performance

2013· article· en· W7136057352 on OpenAlexaff
Jason Suggett, Jolyon Mitchell, Heather Schneider, Rubina Ali, Mark Nagel

Bibliographic record

VenueEuropean Respiratory Journal · 2013
Typearticle
Languageen
FieldMedicine
TopicInhalation and Respiratory Drug Delivery
Canadian institutionsTrudell Medical International (Canada)
Fundersnot available
KeywordsNebulizerExhalationTolerabilityDelivery systemLung functionInhalation

Abstract

fetched live from OpenAlex

RATIONALE: Pulmozyme® is indicated in the management of cystic fibrosis to improve lung function and is typically delivered by continuous nebulization to tidal-breathing patients. During the exhalation phase medication is discharged into the environment. Breath-actuated nebulizers (BANs) only operate during inhalation. This study was designed to evaluate medication output from a BAN configuration (AeroEclipse®-XL/Ombra® compressor (AE-XL); TMI) compared with a continuous nebulizer configuration (PARI LC-plus®/PARI Boy®SX compressor (LC+)). METHODS: Each nebulizer was filled with a 2.5 mL Pulmozyme® ampoule (1 mg/mL dornase alfa) and run until onset of sputtering. Aerosol was captured by a filter at the mouthpiece, and the nebulizer connected to a breathing simulator (tidal volume = 600 mL; duty cycle = 33%; rate = 10 cycles/min). Fine droplet mass (µg < 5.4 µm diameter (FM pulm )) and fine droplet fraction (% < 5.4µm, (FMF pulm ) were determined by Next Generation Impactor operated at 15 L/min with assay for dornase alfa by HPLC. RESULTS: Device (n=10) FMFpulm (%) FMpulm (μg) AE -XL / Ombra 83.3 ± 2.2 428 ± 40 LC+ / Pari Boy SX 83.8 ± 2.2 349 ± 62 CONCLUSIONS: The AE-XL BAN exhibited a little higher delivery of Pulmozyme® to the LC+, although well within the demonstrated patient tolerability (Pulmozyme® Nebuliser solution SPC, Roche). In addition, clinicians should be aware that, unlike the LC+, the operation of the BAN only occurs due to patient inhalation thereby eliminating nearly all fugitive emissions and ensuring delivery to the patient at their own pace.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.030
GPT teacher head0.237
Teacher spread0.207 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2013
Admission routes1
Has abstractyes

Explore more

Same venueEuropean Respiratory Journal→Same topicInhalation and Respiratory Drug Delivery→French-language works237,207→