MétaCan
Menu
Back to cohort
Record W87709141 · doi:10.1093/joneph/19.s9.s76

An improved approach to the patient with metabolic acidosis: a need for four amendments

2006· article· en· W87709141 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueJournal of Nephrology · 2006
Typearticle
Languageen
FieldMedicine
TopicRenal function and acid-base balance
Canadian institutionsUniversity of TorontoSt. Michael's Hospital
Fundersnot available
KeywordsMetabolic acidosisMedicineAcidosisBicarbonateHematocritCreatinineInternal medicineUrineIntensive care medicineUrologyEndocrinology

Abstract

fetched live from OpenAlex

Clinicians should identify life-threatening issues in patients with metabolic acidosis. These threats may be present before therapy begins and/or anticipated after therapy commences. By adding four amendments, short-comings in the commonly used clinical approaches for the diagnosis of metabolic acidosis can be overcome. First, a definition of metabolic acidosis should consider not only the concentration of bicarbonate but also the content of bicarbonate in the extra cellular fluid compartment. The latter requires a quantitative estimate of the ECF volume, which can be obtained using the hematocrit and/or the total protein concentration in plasma. Second, to determine if the basis for metabolic acidosis was the addition of acids or the loss of NaHCO 3 , one must hunt for new anions, not only in plasma, but also in the urine. Third, it is important to measure the venous as well as the arterial PCO2 to assess the capacity to buffer H+ while minimizing H + binding to intracellular proteins. Fourth, to assess the role of the kidney in a patient with metabolic acidosis, the urine osmolal gap and the concentration of creatinine in the urine should be measured to provide an estimate of the rate of excretion of ammonium.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.842
Threshold uncertainty score0.235

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.013
GPT teacher head0.246
Teacher spread0.234 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it