MétaCan
Menu
Back to cohort
Record W890251395 · doi:10.1109/tbcas.2015.2434618

A Microsystem for Magnetic Immunoassay Based on Planar Microcoil Array

2015· article· en· W890251395 on OpenAlexaff
Yushan Zheng, Nan Shang, Pierre S. Haddad, Mohamad Sawan

Bibliographic record

VenueIEEE Transactions on Biomedical Circuits and Systems · 2015
Typearticle
Languageen
FieldEngineering
TopicAcoustic Wave Resonator Technologies
Canadian institutionsUniversité de MontréalPolytechnique Montréal
Fundersnot available
KeywordsMicrocoilMicrosystemPlanarMaterials scienceImmunoassayElectronic circuitLab-on-a-chipIntegrated circuitSensitivity (control systems)OptoelectronicsElectronic engineeringElectrical engineeringNanotechnologyComputer scienceElectromagnetic coilMicrofluidicsEngineering

Abstract

fetched live from OpenAlex

This work focuses on the circuit and system implementation of a microsystem platform for magnetic immunoassay, which is a novel type of diagnostic method using magnetic beads as labels. Three main challenges facing this work-design of a high performance sensor, packaging technique and design of integrated circuits are discussed. Planar microcoil array are exploited as sensor of magnetic beads, whereas ultra thin bottom microplate in traditional ELISA is used for the assay. Main circuits blocks include bidirectional current supply circuit, magnetic field sensing circuit and on-chip temperature sensor. Experiments using mouse IgG with different densities were performed on the proposed platform, results show that a minimum density of 100 pg/mL can be detected, which is a comparable sensitivity to conventional optical ELISA, and a quantitative relationship can be acquired in the range from 1 ng/ml to 1 ug/ml, thus this platform is suitable for quantitative analysis in practical health and environment application and has potential for medical diagnostics, food pathogen detection or water analysis.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.002

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.023
GPT teacher head0.222
Teacher spread0.199 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations14
Published2015
Admission routes1
Has abstractyes

Explore more

Same venueIEEE Transactions on Biomedical Circuits and SystemsSame topicAcoustic Wave Resonator TechnologiesFrench-language works237,207