MétaCan
Menu
Back to cohort
Record W93672273 · doi:10.1155/2011/354546

‘Short’ Double-Balloon Enteroscope for Endoscopic Retrograde Cholangiopancreatography in Patients with a Surgically Altered Upper Gastrointestinal Tract

2011· article· en· W93672273 on OpenAlexaffvenueabout
Soyun Cho, Patarapong Kamalaporn, Gabor Kandel, Paul Kortan, Norman E. Marcon, Gary R. May

Bibliographic record

VenueCanadian Journal of Gastroenterology · 2011
Typearticle
Languageen
FieldImmunology and Microbiology
TopicMedical Device Sterilization and Disinfection
Canadian institutionsUniversity of TorontoSt. Michael's Hospital
Fundersnot available
KeywordsMedicineEndoscopic retrograde cholangiopancreatographyDouble-balloon enteroscopyBalloonAnastomosisSurgeryGastroenterostomyURETEROSCOPEMajor duodenal papillaEndoscopyBillroth IIRoux-en-Y anastomosisRadiologyInternal medicineGastric bypassPancreatitisCancer

Abstract

fetched live from OpenAlex

BACKGROUND: Endoscopic retrograde cholangiopancreatography (ERCP) remains a challenge for endoscopists in patients with surgically altered anatomy of the upper gastrointestinal tract. Double-balloon enteroscopes (DBEs) have revolutionized the ability to access the small bowel. The indication for its therapeutic use is expanding to include ERCP for patients who have undergone small bowel reconstruction. Most of the published experiences in DBE-assisted ERCP have used conventional double-balloon enteroscopes that are 200 cm in length, which do not permit use of the standard ERCP accessories. The authors report their experience with DBE-assisted ERCP using a 'short' DBE in patients with surgically altered anatomy. METHODS: A retrospective review of patients with previous small bowel reconstruction who underwent ERCP with a 'short' DBE at the Centre for Therapeutic Endoscopy and Endoscopic Oncology (Toronto, Ontario) between February 2007 and November 2008 was performed. RESULTS: A total of 20 patients (10 men) with a mean age of 57.9 years (range 26 to 85 years) underwent 29 sessions of ERCP with a DBE. Six patients underwent Billroth II gastroenterostomy, seven patients Roux-en-Y hepaticojejunostomy, five patients Roux-en-Y gastrojejunostomy, one patient Roux-en-Y esophagojejunostomy and one patient a Whipple's operation with choledochojejunostomy. Some patients (n=12 [60%]) underwent previous attempts at ERCP in which the papilla of Vater or bilioenteric anastomosis could not be reached with either a duodenoscope or pediatric colonoscope. All procedures were performed with a commercially available DBE (working length 152 cm, distal end diameter 9.4 mm, channel diameter 2.8 mm). The procedures were performed under conscious sedation with intravenous midazolam, fentanyl and diazepam, except in one patient in whom general anesthesia was administered. Either the papilla of Vater or bilioenteric anastomosis was reached in 25 of 29 cases (86.2%) in a mean duration of 20.8 min (range 5 min to 82 min). Bile duct cannulation was successful in 24 of 25 cases in which the papilla or bilioenteric anastomosis was reached. Therapeutic interventions were successful in 15 patients (24 procedures) including sphincterotomy (n=7), stone extraction (n=9), biliary dilation (n=8), stent placement (n=9) and stent removal (n=8). The mean total duration of the procedures was 70.7 min (range 30 min to 117 min). There were no procedure-related complications. CONCLUSION: DBEs enable successful diagnostic and therapeutic ERCP in patients with a surgically altered anatomy of the upper gastrointestinal tract. It is a safe, feasible and less invasive therapeutic option in this group of patients. Standard 'long' DBEs have limitations of long working length and the need for modified ERCP accessories. 'Short' DBEs are equally as effective in reaching the target limb as standard 'long' DBEs, and overcomes some limitations of long DBEs to result in high success rates for endoscopic therapy.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.013
Threshold uncertainty score0.606

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.216
Teacher spread0.200 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations67
Published2011
Admission routes3
Has abstractyes

Explore more

Same venueCanadian Journal of GastroenterologySame topicMedical Device Sterilization and DisinfectionFrench-language works237,207